{"product_id":"daikin-cassette-splits-for-vrv-systems-1-0-ton-3-6-kw-1-3-hp-12-000-btu-h-fxfsq32arv1-white","title":"Daikin Cassette Splits for VRV Systems 1.0 Ton 3.6 kW 1.3 HP 12,000 Btu\/h FXFSQ32ARV1 White","description":"\u003cp data-start=\"158\" data-end=\"541\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"162\" data-end=\"184\"\u003eDaikin FXFSQ32ARV1\u003c\/strong\u003e is a high-performance VRV ceiling mounted cassette indoor unit designed to deliver comfortable and even air conditioning through its advanced \u003cstrong data-start=\"327\" data-end=\"350\"\u003e360° airflow system\u003c\/strong\u003e. It uses circulation airflow, individual airflow control, and direct airflow to distribute air throughout the room, helping reduce uneven temperatures and cold air pockets at floor level. ❄️\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"543\" data-end=\"546\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"548\" data-end=\"563\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"565\" data-end=\"1181\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"565\" data-end=\"590\"\u003e\n\u003ctr data-start=\"565\" data-end=\"590\"\u003e\n\u003cth data-start=\"565\" data-end=\"575\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"575\" data-end=\"590\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"601\" data-end=\"1181\"\u003e\n\u003ctr data-start=\"601\" data-end=\"623\"\u003e\n\u003ctd data-start=\"601\" data-end=\"613\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"603\" data-end=\"612\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"613\" data-end=\"623\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"624\" data-end=\"651\"\u003e\n\u003ctd data-start=\"624\" data-end=\"636\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"626\" data-end=\"635\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"636\" data-end=\"651\" data-col-size=\"md\"\u003eFXFSQ32ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"652\" data-end=\"679\"\u003e\n\u003ctd data-start=\"652\" data-end=\"665\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"654\" data-end=\"664\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"665\" data-end=\"679\" data-col-size=\"md\"\u003eFXFSQ-ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"680\" data-end=\"727\"\u003e\n\u003ctd data-start=\"680\" data-end=\"699\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"682\" data-end=\"698\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"699\" data-end=\"727\" data-col-size=\"md\"\u003eVRV cassette indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"728\" data-end=\"791\"\u003e\n\u003ctd data-start=\"728\" data-end=\"752\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"730\" data-end=\"751\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"752\" data-end=\"791\" data-col-size=\"md\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"792\" data-end=\"840\"\u003e\n\u003ctd data-start=\"792\" data-end=\"815\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"794\" data-end=\"814\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"815\" data-end=\"840\" data-col-size=\"md\"\u003e3.6 kW \/ 12,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"841\" data-end=\"889\"\u003e\n\u003ctd data-start=\"841\" data-end=\"864\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"843\" data-end=\"863\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"864\" data-end=\"889\" data-col-size=\"md\"\u003e4.0 kW \/ 13,600 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"890\" data-end=\"944\"\u003e\n\u003ctd data-start=\"890\" data-end=\"911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"892\" data-end=\"910\"\u003eAirflow System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"911\" data-end=\"944\" data-col-size=\"md\"\u003e360° airflow \/ all-round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"945\" data-end=\"1021\"\u003e\n\u003ctd data-start=\"945\" data-end=\"967\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"947\" data-end=\"966\"\u003eMain Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"967\" data-end=\"1021\"\u003eCirculation airflow and individual airflow setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1022\" data-end=\"1079\"\u003e\n\u003ctd data-start=\"1022\" data-end=\"1039\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1038\"\u003eDrain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1039\" data-end=\"1079\" data-col-size=\"md\"\u003eStandard drain pump with 850 mm lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1080\" data-end=\"1181\"\u003e\n\u003ctd data-start=\"1080\" data-end=\"1098\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1082\" data-end=\"1097\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1098\" data-end=\"1181\" data-col-size=\"md\"\u003eOffices, shops, restaurants, meeting rooms, showrooms, and commercial interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1183\" data-end=\"1186\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1188\" data-end=\"1207\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1209\" data-end=\"2815\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1209\" data-end=\"1230\"\u003e\n\u003ctr data-start=\"1209\" data-end=\"1230\"\u003e\n\u003cth data-start=\"1209\" data-end=\"1219\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1219\" data-end=\"1230\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1241\" data-end=\"2815\"\u003e\n\u003ctr data-start=\"1241\" data-end=\"1384\"\u003e\n\u003ctd data-start=\"1241\" data-end=\"1273\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1272\"\u003e360° Airflow Distribution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1273\" data-end=\"1384\" data-col-size=\"lg\"\u003eProvides all-round airflow to improve temperature distribution and create a comfortable indoor environment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1385\" data-end=\"1549\"\u003e\n\u003ctd data-start=\"1385\" data-end=\"1411\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1387\" data-end=\"1410\"\u003eCirculation Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1411\" data-end=\"1549\" data-col-size=\"lg\"\u003eStraight, horizontal, and strong airflow travels across the room, reaches the walls, and falls toward the floor for full-room comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1550\" data-end=\"1702\"\u003e\n\u003ctd data-start=\"1550\" data-end=\"1583\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1552\" data-end=\"1582\"\u003eIndividual Airflow Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1583\" data-end=\"1702\" data-col-size=\"lg\"\u003eAirflow direction can be adjusted individually for each discharge outlet to suit room layout and occupant position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1703\" data-end=\"1834\"\u003e\n\u003ctd data-start=\"1703\" data-end=\"1732\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1705\" data-end=\"1731\"\u003eDirect Airflow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1732\" data-end=\"1834\" data-col-size=\"lg\"\u003eHelps direct airflow according to seating areas, working zones, windows, and comfort requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1835\" data-end=\"1970\"\u003e\n\u003ctd data-start=\"1835\" data-end=\"1856\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1837\" data-end=\"1855\"\u003eNew Wide Flaps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1856\" data-end=\"1970\" data-col-size=\"lg\"\u003eWide flaps increase airflow straightness and help improve coverage compared with conventional cassette models.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1971\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"1971\" data-end=\"2000\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1973\" data-end=\"1999\"\u003eCeiling Dirt Reduction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2000\" data-end=\"2094\" data-col-size=\"lg\"\u003eNew wide flap construction helps direct airflow downward to reduce ceiling dirt and grime.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2205\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2130\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2097\" data-end=\"2129\"\u003eOptimized Horizontal Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2130\" data-end=\"2205\" data-col-size=\"lg\"\u003eMaintains a more horizontal airflow route even when the flap is raised.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2206\" data-end=\"2321\"\u003e\n\u003ctd data-start=\"2206\" data-end=\"2232\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2208\" data-end=\"2231\"\u003eTwo-Way Flow Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2232\" data-end=\"2321\" data-col-size=\"lg\"\u003eSelected outlets can be controlled to create stronger airflow in required directions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2322\" data-end=\"2439\"\u003e\n\u003ctd data-start=\"2322\" data-end=\"2350\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2324\" data-end=\"2349\"\u003eImproved Air Velocity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2350\" data-end=\"2439\" data-col-size=\"lg\"\u003eTwo-way flow helps increase air velocity for powerful and effective air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2440\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2440\" data-end=\"2468\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2442\" data-end=\"2467\"\u003eEnergy Saving Comfort\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2468\" data-end=\"2564\" data-col-size=\"lg\"\u003eHelps save energy by reducing uneven room temperature and improving comfort across the room.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2688\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2596\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2567\" data-end=\"2595\"\u003eRoom Layout Adaptability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2596\" data-end=\"2688\" data-col-size=\"lg\"\u003eSuitable for different layouts in offices, shops, restaurants, and commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2689\" data-end=\"2815\"\u003e\n\u003ctd data-start=\"2689\" data-end=\"2715\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2691\" data-end=\"2714\"\u003eStandard Drain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2715\" data-end=\"2815\" data-col-size=\"lg\"\u003eBuilt-in drain pump supports condensate lift up to \u003cstrong data-start=\"2768\" data-end=\"2778\"\u003e850 mm\u003c\/strong\u003e for flexible ceiling installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2817\" data-end=\"2820\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2822\" data-end=\"2845\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2847\" data-end=\"3739\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2847\" data-end=\"2874\"\u003e\n\u003ctr data-start=\"2847\" data-end=\"2874\"\u003e\n\u003cth data-start=\"2847\" data-end=\"2863\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2863\" data-end=\"2874\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2885\" data-end=\"3739\"\u003e\n\u003ctr data-start=\"2885\" data-end=\"2912\"\u003e\n\u003ctd data-start=\"2885\" data-end=\"2897\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2887\" data-end=\"2896\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2897\" data-end=\"2912\" data-col-size=\"sm\"\u003eFXFSQ32ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2913\" data-end=\"2963\"\u003e\n\u003ctd data-start=\"2913\" data-end=\"2932\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2915\" data-end=\"2931\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2932\" data-end=\"2963\" data-col-size=\"sm\"\u003e1-phase, 220–240V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2964\" data-end=\"3012\"\u003e\n\u003ctd data-start=\"2964\" data-end=\"2987\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2966\" data-end=\"2986\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2987\" data-end=\"3012\" data-col-size=\"sm\"\u003e12,300 Btu\/h \/ 3.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3013\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3013\" data-end=\"3036\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3015\" data-end=\"3035\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3036\" data-end=\"3061\" data-col-size=\"sm\"\u003e13,600 Btu\/h \/ 4.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3101\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3075\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3064\" data-end=\"3074\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3075\" data-end=\"3101\"\u003eGalvanized steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3102\" data-end=\"3166\"\u003e\n\u003ctd data-start=\"3102\" data-end=\"3141\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3104\" data-end=\"3140\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3141\" data-end=\"3166\" data-col-size=\"sm\"\u003e17 \/ 12.5 \/ 11 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3167\" data-end=\"3229\"\u003e\n\u003ctd data-start=\"3167\" data-end=\"3206\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3169\" data-end=\"3205\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3206\" data-end=\"3229\" data-col-size=\"sm\"\u003e600 \/ 441 \/ 388 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3230\" data-end=\"3290\"\u003e\n\u003ctd data-start=\"3230\" data-end=\"3268\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3232\" data-end=\"3267\"\u003eSound Level High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3268\" data-end=\"3290\" data-col-size=\"sm\"\u003e35 \/ 29 \/ 27 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3291\" data-end=\"3340\"\u003e\n\u003ctd data-start=\"3291\" data-end=\"3318\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3293\" data-end=\"3317\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3318\" data-end=\"3340\" data-col-size=\"sm\"\u003e256 × 840 × 840 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3341\" data-end=\"3371\"\u003e\n\u003ctd data-start=\"3341\" data-end=\"3362\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3343\" data-end=\"3361\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3362\" data-end=\"3371\" data-col-size=\"sm\"\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3372\" data-end=\"3417\"\u003e\n\u003ctd data-start=\"3372\" data-end=\"3401\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3374\" data-end=\"3400\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3401\" data-end=\"3417\" data-col-size=\"sm\"\u003e6.4 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3418\" data-end=\"3461\"\u003e\n\u003ctd data-start=\"3418\" data-end=\"3444\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3420\" data-end=\"3443\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3444\" data-end=\"3461\" data-col-size=\"sm\"\u003e12.7 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3462\" data-end=\"3501\"\u003e\n\u003ctd data-start=\"3462\" data-end=\"3485\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3464\" data-end=\"3484\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3485\" data-end=\"3501\" data-col-size=\"sm\"\u003eDia. 26 hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3502\" data-end=\"3557\"\u003e\n\u003ctd data-start=\"3502\" data-end=\"3529\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3504\" data-end=\"3528\"\u003eStandard Panel Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3529\" data-end=\"3557\"\u003eBYCQ125EAF9, Fresh White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3558\" data-end=\"3612\"\u003e\n\u003ctd data-start=\"3558\" data-end=\"3591\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3560\" data-end=\"3590\"\u003ePanel Dimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3591\" data-end=\"3612\" data-col-size=\"sm\"\u003e50 × 950 × 950 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3613\" data-end=\"3642\"\u003e\n\u003ctd data-start=\"3613\" data-end=\"3632\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3615\" data-end=\"3631\"\u003ePanel Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3632\" data-end=\"3642\" data-col-size=\"sm\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3643\" data-end=\"3675\"\u003e\n\u003ctd data-start=\"3643\" data-end=\"3665\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3645\" data-end=\"3664\"\u003eDrain Pump Lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3665\" data-end=\"3675\" data-col-size=\"sm\"\u003e850 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3676\" data-end=\"3739\"\u003e\n\u003ctd data-start=\"3676\" data-end=\"3700\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3678\" data-end=\"3699\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3700\" data-end=\"3739\" data-col-size=\"sm\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3741\" data-end=\"3744\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3746\" data-end=\"3766\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3768\" data-end=\"4445\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3768\" data-end=\"3798\"\u003e\n\u003ctr data-start=\"3768\" data-end=\"3798\"\u003e\n\u003cth data-start=\"3768\" data-end=\"3787\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3787\" data-end=\"3798\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3809\" data-end=\"4445\"\u003e\n\u003ctr data-start=\"3809\" data-end=\"3921\"\u003e\n\u003ctd data-start=\"3809\" data-end=\"3823\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3811\" data-end=\"3822\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3823\" data-end=\"3921\" data-col-size=\"md\"\u003eHelps provide balanced airflow for desks, workstations, meeting areas, and zones near windows.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3922\" data-end=\"4033\"\u003e\n\u003ctd data-start=\"3922\" data-end=\"3940\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3924\" data-end=\"3939\"\u003eRestaurants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3940\" data-end=\"4033\" data-col-size=\"md\"\u003eSuitable for dining spaces where even comfort is required across different seating areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4034\" data-end=\"4143\"\u003e\n\u003ctd data-start=\"4034\" data-end=\"4053\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4036\" data-end=\"4052\"\u003eRetail Shops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4053\" data-end=\"4143\" data-col-size=\"md\"\u003eProvides comfortable cooling for customer areas, counters, and product display spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4144\" data-end=\"4231\"\u003e\n\u003ctd data-start=\"4144\" data-end=\"4160\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4146\" data-end=\"4159\"\u003eShowrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4160\" data-end=\"4231\" data-col-size=\"md\"\u003eHelps maintain consistent comfort across open commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4232\" data-end=\"4324\"\u003e\n\u003ctd data-start=\"4232\" data-end=\"4252\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4234\" data-end=\"4251\"\u003eMeeting Rooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4252\" data-end=\"4324\" data-col-size=\"md\"\u003eIndividual airflow settings help reduce direct airflow on occupants.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4325\" data-end=\"4445\"\u003e\n\u003ctd data-start=\"4325\" data-end=\"4352\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4327\" data-end=\"4351\"\u003eCommercial Interiors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4352\" data-end=\"4445\" data-col-size=\"md\"\u003eIdeal for ceiling cassette VRV applications requiring flexible and even air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4447\" data-end=\"4450\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4452\" data-end=\"4468\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4470\" data-end=\"4988\"\u003e\n\u003cli data-section-id=\"jnu00p\" data-start=\"4470\" data-end=\"4526\"\u003eEfficient \u003cstrong data-start=\"4482\" data-end=\"4526\"\u003eVRV ceiling mounted cassette indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w45r96\" data-start=\"4527\" data-end=\"4574\"\u003eCooling capacity of \u003cstrong data-start=\"4549\" data-end=\"4574\"\u003e3.6 kW \/ 12,300 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17zsvs8\" data-start=\"4575\" data-end=\"4622\"\u003eHeating capacity of \u003cstrong data-start=\"4597\" data-end=\"4622\"\u003e4.0 kW \/ 13,600 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qlbvxb\" data-start=\"4623\" data-end=\"4677\"\u003e\n\u003cstrong data-start=\"4625\" data-end=\"4651\"\u003e360° all-round airflow\u003c\/strong\u003e for improved room comfort\u003c\/li\u003e\n\u003cli data-section-id=\"gjinmg\" data-start=\"4678\" data-end=\"4733\"\u003eCirculation airflow helps cool the entire room evenly\u003c\/li\u003e\n\u003cli data-section-id=\"3f1vm1\" data-start=\"4734\" data-end=\"4778\"\u003eIndividual airflow control for each outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1hz8nbh\" data-start=\"4779\" data-end=\"4827\"\u003eNew wide flap design improves airflow coverage\u003c\/li\u003e\n\u003cli data-section-id=\"1itzf8d\" data-start=\"4828\" data-end=\"4865\"\u003eHelps reduce ceiling dirt and grime\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4f8\" data-start=\"4866\" data-end=\"4908\"\u003eBuilt-in drain pump with \u003cstrong data-start=\"4893\" data-end=\"4908\"\u003e850 mm lift\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"196rmyp\" data-start=\"4909\" data-end=\"4988\"\u003eSuitable for offices, restaurants, shops, showrooms, and commercial spaces ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47830323527916,"sku":null,"price":3549.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606240928-Copy_7.jpg?v=1782467917","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-cassette-splits-for-vrv-systems-1-0-ton-3-6-kw-1-3-hp-12-000-btu-h-fxfsq32arv1-white","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}