{"product_id":"daikin-cassette-splits-for-vrv-systems-1-2-ton-4-5-kw-1-6-hp-15-000-btu-h-fxfsq40arv1-black","title":"Daikin Cassette Splits for VRV Systems 1.2 Ton 4.5 kW 1.6 HP 15,000 Btu\/h FXFSQ40ARV1 Black","description":"\u003cp data-start=\"158\" data-end=\"527\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"162\" data-end=\"184\"\u003eDaikin FXFSQ40ARV1\u003c\/strong\u003e is a VRV ceiling mounted cassette indoor unit designed to provide comfortable and even air conditioning through its advanced \u003cstrong data-start=\"310\" data-end=\"333\"\u003e360° airflow system\u003c\/strong\u003e. It uses circulation airflow, individual airflow control, and direct airflow to distribute air across the entire room, helping reduce uneven temperatures and cold air pockets at floor level. ❄️\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"529\" data-end=\"532\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"534\" data-end=\"549\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"551\" data-end=\"1167\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"551\" data-end=\"576\"\u003e\n\u003ctr data-start=\"551\" data-end=\"576\"\u003e\n\u003cth data-start=\"551\" data-end=\"561\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"561\" data-end=\"576\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"587\" data-end=\"1167\"\u003e\n\u003ctr data-start=\"587\" data-end=\"609\"\u003e\n\u003ctd data-start=\"587\" data-end=\"599\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"589\" data-end=\"598\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"599\" data-end=\"609\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"610\" data-end=\"637\"\u003e\n\u003ctd data-start=\"610\" data-end=\"622\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"612\" data-end=\"621\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"622\" data-end=\"637\" data-col-size=\"md\"\u003eFXFSQ40ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"638\" data-end=\"665\"\u003e\n\u003ctd data-start=\"638\" data-end=\"651\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"640\" data-end=\"650\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"651\" data-end=\"665\" data-col-size=\"md\"\u003eFXFSQ-ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"666\" data-end=\"713\"\u003e\n\u003ctd data-start=\"666\" data-end=\"685\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"668\" data-end=\"684\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"685\" data-end=\"713\" data-col-size=\"md\"\u003eVRV cassette indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"714\" data-end=\"777\"\u003e\n\u003ctd data-start=\"714\" data-end=\"738\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"716\" data-end=\"737\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"738\" data-end=\"777\" data-col-size=\"md\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"778\" data-end=\"826\"\u003e\n\u003ctd data-start=\"778\" data-end=\"801\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"780\" data-end=\"800\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"801\" data-end=\"826\" data-col-size=\"md\"\u003e4.5 kW \/ 15,400 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"827\" data-end=\"875\"\u003e\n\u003ctd data-start=\"827\" data-end=\"850\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"829\" data-end=\"849\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"850\" data-end=\"875\" data-col-size=\"md\"\u003e5.0 kW \/ 17,100 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"876\" data-end=\"930\"\u003e\n\u003ctd data-start=\"876\" data-end=\"897\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"878\" data-end=\"896\"\u003eAirflow System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"897\" data-end=\"930\" data-col-size=\"md\"\u003e360° airflow \/ all-round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"931\" data-end=\"1007\"\u003e\n\u003ctd data-start=\"931\" data-end=\"953\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"933\" data-end=\"952\"\u003eMain Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"953\" data-end=\"1007\" data-col-size=\"md\"\u003eCirculation airflow and individual airflow setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1008\" data-end=\"1065\"\u003e\n\u003ctd data-start=\"1008\" data-end=\"1025\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1010\" data-end=\"1024\"\u003eDrain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1025\" data-end=\"1065\" data-col-size=\"md\"\u003eStandard drain pump with 850 mm lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1066\" data-end=\"1167\"\u003e\n\u003ctd data-start=\"1066\" data-end=\"1084\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1068\" data-end=\"1083\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1084\" data-end=\"1167\" data-col-size=\"md\"\u003eOffices, shops, restaurants, meeting rooms, showrooms, and commercial interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1169\" data-end=\"1172\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1174\" data-end=\"1193\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1195\" data-end=\"2801\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1195\" data-end=\"1216\"\u003e\n\u003ctr data-start=\"1195\" data-end=\"1216\"\u003e\n\u003cth data-start=\"1195\" data-end=\"1205\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1205\" data-end=\"1216\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1227\" data-end=\"2801\"\u003e\n\u003ctr data-start=\"1227\" data-end=\"1370\"\u003e\n\u003ctd data-start=\"1227\" data-end=\"1259\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1229\" data-end=\"1258\"\u003e360° Airflow Distribution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1259\" data-end=\"1370\" data-col-size=\"lg\"\u003eProvides all-round airflow to improve temperature distribution and create a comfortable indoor environment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1371\" data-end=\"1535\"\u003e\n\u003ctd data-start=\"1371\" data-end=\"1397\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1396\"\u003eCirculation Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1397\" data-end=\"1535\" data-col-size=\"lg\"\u003eStraight, horizontal, and strong airflow travels across the room, reaches the walls, and falls toward the floor for full-room comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1536\" data-end=\"1688\"\u003e\n\u003ctd data-start=\"1536\" data-end=\"1569\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1568\"\u003eIndividual Airflow Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1569\" data-end=\"1688\" data-col-size=\"lg\"\u003eAirflow direction can be adjusted individually for each discharge outlet to suit room layout and occupant position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1689\" data-end=\"1820\"\u003e\n\u003ctd data-start=\"1689\" data-end=\"1718\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1691\" data-end=\"1717\"\u003eDirect Airflow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1718\" data-end=\"1820\" data-col-size=\"lg\"\u003eHelps direct airflow according to seating areas, working zones, windows, and comfort requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1821\" data-end=\"1956\"\u003e\n\u003ctd data-start=\"1821\" data-end=\"1842\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1823\" data-end=\"1841\"\u003eNew Wide Flaps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1842\" data-end=\"1956\" data-col-size=\"lg\"\u003eWide flaps increase airflow straightness and help improve coverage compared with conventional cassette models.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1957\" data-end=\"2080\"\u003e\n\u003ctd data-start=\"1957\" data-end=\"1986\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1959\" data-end=\"1985\"\u003eCeiling Dirt Reduction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1986\" data-end=\"2080\" data-col-size=\"lg\"\u003eNew wide flap construction helps direct airflow downward to reduce ceiling dirt and grime.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2081\" data-end=\"2191\"\u003e\n\u003ctd data-start=\"2081\" data-end=\"2116\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2083\" data-end=\"2115\"\u003eOptimized Horizontal Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2116\" data-end=\"2191\" data-col-size=\"lg\"\u003eMaintains a more horizontal airflow route even when the flap is raised.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2192\" data-end=\"2307\"\u003e\n\u003ctd data-start=\"2192\" data-end=\"2218\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2194\" data-end=\"2217\"\u003eTwo-Way Flow Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2218\" data-end=\"2307\" data-col-size=\"lg\"\u003eSelected outlets can be controlled to create stronger airflow in required directions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2308\" data-end=\"2425\"\u003e\n\u003ctd data-start=\"2308\" data-end=\"2336\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2310\" data-end=\"2335\"\u003eImproved Air Velocity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2336\" data-end=\"2425\" data-col-size=\"lg\"\u003eTwo-way flow helps increase air velocity for powerful and effective air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2426\" data-end=\"2550\"\u003e\n\u003ctd data-start=\"2426\" data-end=\"2454\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2428\" data-end=\"2453\"\u003eEnergy Saving Comfort\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2454\" data-end=\"2550\" data-col-size=\"lg\"\u003eHelps save energy by reducing uneven room temperature and improving comfort across the room.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2551\" data-end=\"2674\"\u003e\n\u003ctd data-start=\"2551\" data-end=\"2582\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2553\" data-end=\"2581\"\u003eRoom Layout Adaptability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2674\" data-col-size=\"lg\"\u003eSuitable for different layouts in offices, shops, restaurants, and commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2675\" data-end=\"2801\"\u003e\n\u003ctd data-start=\"2675\" data-end=\"2701\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2677\" data-end=\"2700\"\u003eStandard Drain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2701\" data-end=\"2801\" data-col-size=\"lg\"\u003eBuilt-in drain pump supports condensate lift up to \u003cstrong data-start=\"2754\" data-end=\"2764\"\u003e850 mm\u003c\/strong\u003e for flexible ceiling installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2803\" data-end=\"2806\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2808\" data-end=\"2831\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2833\" data-end=\"3725\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2833\" data-end=\"2860\"\u003e\n\u003ctr data-start=\"2833\" data-end=\"2860\"\u003e\n\u003cth data-start=\"2833\" data-end=\"2849\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2849\" data-end=\"2860\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2871\" data-end=\"3725\"\u003e\n\u003ctr data-start=\"2871\" data-end=\"2898\"\u003e\n\u003ctd data-start=\"2871\" data-end=\"2883\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2873\" data-end=\"2882\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2883\" data-end=\"2898\" data-col-size=\"sm\"\u003eFXFSQ40ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2899\" data-end=\"2949\"\u003e\n\u003ctd data-start=\"2899\" data-end=\"2918\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2901\" data-end=\"2917\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2918\" data-end=\"2949\" data-col-size=\"sm\"\u003e1-phase, 220–240V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2950\" data-end=\"2998\"\u003e\n\u003ctd data-start=\"2950\" data-end=\"2973\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2952\" data-end=\"2972\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2973\" data-end=\"2998\" data-col-size=\"sm\"\u003e15,400 Btu\/h \/ 4.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2999\" data-end=\"3047\"\u003e\n\u003ctd data-start=\"2999\" data-end=\"3022\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3021\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3022\" data-end=\"3047\" data-col-size=\"sm\"\u003e17,100 Btu\/h \/ 5.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3048\" data-end=\"3087\"\u003e\n\u003ctd data-start=\"3048\" data-end=\"3061\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3050\" data-end=\"3060\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3061\" data-end=\"3087\" data-col-size=\"sm\"\u003eGalvanized steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3088\" data-end=\"3152\"\u003e\n\u003ctd data-start=\"3088\" data-end=\"3127\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3090\" data-end=\"3126\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3127\" data-end=\"3152\" data-col-size=\"sm\"\u003e17 \/ 12.5 \/ 11 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3153\" data-end=\"3215\"\u003e\n\u003ctd data-start=\"3153\" data-end=\"3192\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3155\" data-end=\"3191\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3192\" data-end=\"3215\" data-col-size=\"sm\"\u003e600 \/ 441 \/ 388 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3216\" data-end=\"3276\"\u003e\n\u003ctd data-start=\"3216\" data-end=\"3254\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3218\" data-end=\"3253\"\u003eSound Level High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3254\" data-end=\"3276\" data-col-size=\"sm\"\u003e35 \/ 29 \/ 27 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3277\" data-end=\"3326\"\u003e\n\u003ctd data-start=\"3277\" data-end=\"3304\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3279\" data-end=\"3303\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3304\" data-end=\"3326\" data-col-size=\"sm\"\u003e256 × 840 × 840 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3327\" data-end=\"3357\"\u003e\n\u003ctd data-start=\"3327\" data-end=\"3348\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3329\" data-end=\"3347\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3348\" data-end=\"3357\" data-col-size=\"sm\"\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3358\" data-end=\"3403\"\u003e\n\u003ctd data-start=\"3358\" data-end=\"3387\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3360\" data-end=\"3386\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3387\" data-end=\"3403\" data-col-size=\"sm\"\u003e6.4 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3404\" data-end=\"3447\"\u003e\n\u003ctd data-start=\"3404\" data-end=\"3430\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3406\" data-end=\"3429\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3430\" data-end=\"3447\" data-col-size=\"sm\"\u003e12.7 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3448\" data-end=\"3487\"\u003e\n\u003ctd data-start=\"3448\" data-end=\"3471\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3450\" data-end=\"3470\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3471\" data-end=\"3487\" data-col-size=\"sm\"\u003eDia. 26 hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3488\" data-end=\"3543\"\u003e\n\u003ctd data-start=\"3488\" data-end=\"3515\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3490\" data-end=\"3514\"\u003eStandard Panel Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3515\" data-end=\"3543\" data-col-size=\"sm\"\u003eBYCQ125EAF9, Fresh White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3544\" data-end=\"3598\"\u003e\n\u003ctd data-start=\"3544\" data-end=\"3577\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3546\" data-end=\"3576\"\u003ePanel Dimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3577\" data-end=\"3598\" data-col-size=\"sm\"\u003e50 × 950 × 950 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3599\" data-end=\"3628\"\u003e\n\u003ctd data-start=\"3599\" data-end=\"3618\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3601\" data-end=\"3617\"\u003ePanel Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3618\" data-end=\"3628\" data-col-size=\"sm\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3629\" data-end=\"3661\"\u003e\n\u003ctd data-start=\"3629\" data-end=\"3651\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3631\" data-end=\"3650\"\u003eDrain Pump Lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3651\" data-end=\"3661\" data-col-size=\"sm\"\u003e850 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3662\" data-end=\"3725\"\u003e\n\u003ctd data-start=\"3662\" data-end=\"3686\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3664\" data-end=\"3685\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3686\" data-end=\"3725\" data-col-size=\"sm\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3727\" data-end=\"3730\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3732\" data-end=\"3752\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3754\" data-end=\"4431\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3754\" data-end=\"3784\"\u003e\n\u003ctr data-start=\"3754\" data-end=\"3784\"\u003e\n\u003cth data-start=\"3754\" data-end=\"3773\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3773\" data-end=\"3784\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3795\" data-end=\"4431\"\u003e\n\u003ctr data-start=\"3795\" data-end=\"3907\"\u003e\n\u003ctd data-start=\"3795\" data-end=\"3809\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3797\" data-end=\"3808\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3809\" data-end=\"3907\" data-col-size=\"md\"\u003eHelps provide balanced airflow for desks, workstations, meeting areas, and zones near windows.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3908\" data-end=\"4019\"\u003e\n\u003ctd data-start=\"3908\" data-end=\"3926\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3910\" data-end=\"3925\"\u003eRestaurants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3926\" data-end=\"4019\" data-col-size=\"md\"\u003eSuitable for dining spaces where even comfort is required across different seating areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4020\" data-end=\"4129\"\u003e\n\u003ctd data-start=\"4020\" data-end=\"4039\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4022\" data-end=\"4038\"\u003eRetail Shops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4039\" data-end=\"4129\" data-col-size=\"md\"\u003eProvides comfortable cooling for customer areas, counters, and product display spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4130\" data-end=\"4217\"\u003e\n\u003ctd data-start=\"4130\" data-end=\"4146\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4132\" data-end=\"4145\"\u003eShowrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4146\" data-end=\"4217\" data-col-size=\"md\"\u003eHelps maintain consistent comfort across open commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4218\" data-end=\"4310\"\u003e\n\u003ctd data-start=\"4218\" data-end=\"4238\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4220\" data-end=\"4237\"\u003eMeeting Rooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4238\" data-end=\"4310\" data-col-size=\"md\"\u003eIndividual airflow settings help reduce direct airflow on occupants.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4311\" data-end=\"4431\"\u003e\n\u003ctd data-start=\"4311\" data-end=\"4338\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4313\" data-end=\"4337\"\u003eCommercial Interiors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4338\" data-end=\"4431\" data-col-size=\"md\"\u003eIdeal for ceiling cassette VRV applications requiring flexible and even air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4433\" data-end=\"4436\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4438\" data-end=\"4454\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4456\" data-end=\"4974\"\u003e\n\u003cli data-section-id=\"jnu00p\" data-start=\"4456\" data-end=\"4512\"\u003eEfficient \u003cstrong data-start=\"4468\" data-end=\"4512\"\u003eVRV ceiling mounted cassette indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2x2j0e\" data-start=\"4513\" data-end=\"4560\"\u003eCooling capacity of \u003cstrong data-start=\"4535\" data-end=\"4560\"\u003e4.5 kW \/ 15,400 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tfq7e\" data-start=\"4561\" data-end=\"4608\"\u003eHeating capacity of \u003cstrong data-start=\"4583\" data-end=\"4608\"\u003e5.0 kW \/ 17,100 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qlbvxb\" data-start=\"4609\" data-end=\"4663\"\u003e\n\u003cstrong data-start=\"4611\" data-end=\"4637\"\u003e360° all-round airflow\u003c\/strong\u003e for improved room comfort\u003c\/li\u003e\n\u003cli data-section-id=\"gjinmg\" data-start=\"4664\" data-end=\"4719\"\u003eCirculation airflow helps cool the entire room evenly\u003c\/li\u003e\n\u003cli data-section-id=\"3f1vm1\" data-start=\"4720\" data-end=\"4764\"\u003eIndividual airflow control for each outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1hz8nbh\" data-start=\"4765\" data-end=\"4813\"\u003eNew wide flap design improves airflow coverage\u003c\/li\u003e\n\u003cli data-section-id=\"1itzf8d\" data-start=\"4814\" data-end=\"4851\"\u003eHelps reduce ceiling dirt and grime\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4f8\" data-start=\"4852\" data-end=\"4894\"\u003eBuilt-in drain pump with \u003cstrong data-start=\"4879\" data-end=\"4894\"\u003e850 mm lift\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"196rmyp\" data-start=\"4895\" data-end=\"4974\"\u003eSuitable for offices, restaurants, shops, showrooms, and commercial spaces ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47830317433068,"sku":null,"price":3719.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606241011-Copy_6_-Copy.jpg?v=1782467228","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-cassette-splits-for-vrv-systems-1-2-ton-4-5-kw-1-6-hp-15-000-btu-h-fxfsq40arv1-black","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}