{"product_id":"daikin-cassette-splits-for-vrv-systems-2-0-ton-7-0-kw-2-6-hp-24-000-btu-h-fxfsq63arv1-black","title":"Daikin Cassette Splits for VRV Systems 2.0 Ton | 7.0 kW | 2.6 HP | 24,000 Btu\/h FXFSQ63ARV1 Black","description":"\u003cp data-start=\"158\" data-end=\"537\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"162\" data-end=\"184\"\u003eDaikin FXFSQ63ARV1\u003c\/strong\u003e is a high-performance VRV ceiling mounted cassette indoor unit designed to provide comfortable and even air conditioning through its advanced \u003cstrong data-start=\"327\" data-end=\"350\"\u003e360° airflow system\u003c\/strong\u003e. It uses circulation airflow, individual airflow control, and direct airflow to distribute air across the room, helping reduce uneven temperatures and cold air pockets at floor level. ❄️\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"539\" data-end=\"542\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"544\" data-end=\"559\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"561\" data-end=\"1177\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"561\" data-end=\"586\"\u003e\n\u003ctr data-start=\"561\" data-end=\"586\"\u003e\n\u003cth data-start=\"561\" data-end=\"571\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"571\" data-end=\"586\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"597\" data-end=\"1177\"\u003e\n\u003ctr data-start=\"597\" data-end=\"619\"\u003e\n\u003ctd data-start=\"597\" data-end=\"609\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"599\" data-end=\"608\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"609\" data-end=\"619\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"620\" data-end=\"647\"\u003e\n\u003ctd data-start=\"620\" data-end=\"632\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"622\" data-end=\"631\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"632\" data-end=\"647\" data-col-size=\"md\"\u003eFXFSQ63ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"648\" data-end=\"675\"\u003e\n\u003ctd data-start=\"648\" data-end=\"661\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"650\" data-end=\"660\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"661\" data-end=\"675\" data-col-size=\"md\"\u003eFXFSQ-ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"676\" data-end=\"723\"\u003e\n\u003ctd data-start=\"676\" data-end=\"695\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"678\" data-end=\"694\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"695\" data-end=\"723\" data-col-size=\"md\"\u003eVRV cassette indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"724\" data-end=\"787\"\u003e\n\u003ctd data-start=\"724\" data-end=\"748\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"726\" data-end=\"747\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"748\" data-end=\"787\" data-col-size=\"md\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"788\" data-end=\"836\"\u003e\n\u003ctd data-start=\"788\" data-end=\"811\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"790\" data-end=\"810\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"811\" data-end=\"836\" data-col-size=\"md\"\u003e7.1 kW \/ 24,200 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"837\" data-end=\"885\"\u003e\n\u003ctd data-start=\"837\" data-end=\"860\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"839\" data-end=\"859\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"860\" data-end=\"885\" data-col-size=\"md\"\u003e8.0 kW \/ 27,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"886\" data-end=\"940\"\u003e\n\u003ctd data-start=\"886\" data-end=\"907\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"888\" data-end=\"906\"\u003eAirflow System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"907\" data-end=\"940\" data-col-size=\"md\"\u003e360° airflow \/ all-round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"941\" data-end=\"1017\"\u003e\n\u003ctd data-start=\"941\" data-end=\"963\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"943\" data-end=\"962\"\u003eMain Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"963\" data-end=\"1017\" data-col-size=\"md\"\u003eCirculation airflow and individual airflow setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1018\" data-end=\"1075\"\u003e\n\u003ctd data-start=\"1018\" data-end=\"1035\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1034\"\u003eDrain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1035\" data-end=\"1075\" data-col-size=\"md\"\u003eStandard drain pump with 850 mm lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1076\" data-end=\"1177\"\u003e\n\u003ctd data-start=\"1076\" data-end=\"1094\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1078\" data-end=\"1093\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1094\" data-end=\"1177\" data-col-size=\"md\"\u003eOffices, shops, restaurants, meeting rooms, showrooms, and commercial interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1179\" data-end=\"1182\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1184\" data-end=\"1203\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1205\" data-end=\"2817\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1205\" data-end=\"1226\"\u003e\n\u003ctr data-start=\"1205\" data-end=\"1226\"\u003e\n\u003cth data-start=\"1205\" data-end=\"1215\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1215\" data-end=\"1226\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1237\" data-end=\"2817\"\u003e\n\u003ctr data-start=\"1237\" data-end=\"1386\"\u003e\n\u003ctd data-start=\"1237\" data-end=\"1269\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1239\" data-end=\"1268\"\u003e360° Airflow Distribution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1269\" data-end=\"1386\" data-col-size=\"lg\"\u003eProvides all-round airflow to improve room temperature distribution and deliver a comfortable indoor environment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1387\" data-end=\"1551\"\u003e\n\u003ctd data-start=\"1387\" data-end=\"1413\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1412\"\u003eCirculation Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1413\" data-end=\"1551\" data-col-size=\"lg\"\u003eStraight, horizontal, and strong airflow travels across the room, reaches the walls, and falls toward the floor for full-room comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1552\" data-end=\"1704\"\u003e\n\u003ctd data-start=\"1552\" data-end=\"1585\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1554\" data-end=\"1584\"\u003eIndividual Airflow Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1585\" data-end=\"1704\" data-col-size=\"lg\"\u003eAirflow direction can be adjusted individually for each discharge outlet to suit room layout and occupant position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1705\" data-end=\"1836\"\u003e\n\u003ctd data-start=\"1705\" data-end=\"1734\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1707\" data-end=\"1733\"\u003eDirect Airflow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1734\" data-end=\"1836\" data-col-size=\"lg\"\u003eHelps direct airflow according to seating areas, working zones, windows, and comfort requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1837\" data-end=\"1972\"\u003e\n\u003ctd data-start=\"1837\" data-end=\"1858\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1839\" data-end=\"1857\"\u003eNew Wide Flaps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1858\" data-end=\"1972\" data-col-size=\"lg\"\u003eWide flaps increase airflow straightness and help improve coverage compared with conventional cassette models.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1973\" data-end=\"2096\"\u003e\n\u003ctd data-start=\"1973\" data-end=\"2002\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1975\" data-end=\"2001\"\u003eCeiling Dirt Reduction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2002\" data-end=\"2096\" data-col-size=\"lg\"\u003eNew wide flap construction helps direct airflow downward to reduce ceiling dirt and grime.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2097\" data-end=\"2207\"\u003e\n\u003ctd data-start=\"2097\" data-end=\"2132\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2099\" data-end=\"2131\"\u003eOptimized Horizontal Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2132\" data-end=\"2207\" data-col-size=\"lg\"\u003eMaintains a more horizontal airflow route even when the flap is raised.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2208\" data-end=\"2323\"\u003e\n\u003ctd data-start=\"2208\" data-end=\"2234\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2210\" data-end=\"2233\"\u003eTwo-Way Flow Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2234\" data-end=\"2323\" data-col-size=\"lg\"\u003eSelected outlets can be controlled to create stronger airflow in required directions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2324\" data-end=\"2441\"\u003e\n\u003ctd data-start=\"2324\" data-end=\"2352\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2326\" data-end=\"2351\"\u003eImproved Air Velocity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2352\" data-end=\"2441\" data-col-size=\"lg\"\u003eTwo-way flow helps increase air velocity for powerful and effective air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2442\" data-end=\"2566\"\u003e\n\u003ctd data-start=\"2442\" data-end=\"2470\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2444\" data-end=\"2469\"\u003eEnergy Saving Comfort\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2470\" data-end=\"2566\" data-col-size=\"lg\"\u003eHelps save energy by reducing uneven room temperature and improving comfort across the room.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2567\" data-end=\"2690\"\u003e\n\u003ctd data-start=\"2567\" data-end=\"2598\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2569\" data-end=\"2597\"\u003eRoom Layout Adaptability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2598\" data-end=\"2690\" data-col-size=\"lg\"\u003eSuitable for different layouts in offices, shops, restaurants, and commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2691\" data-end=\"2817\"\u003e\n\u003ctd data-start=\"2691\" data-end=\"2717\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2693\" data-end=\"2716\"\u003eStandard Drain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2717\" data-end=\"2817\" data-col-size=\"lg\"\u003eBuilt-in drain pump supports condensate lift up to \u003cstrong data-start=\"2770\" data-end=\"2780\"\u003e850 mm\u003c\/strong\u003e for flexible ceiling installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2819\" data-end=\"2822\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2824\" data-end=\"2847\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2849\" data-end=\"3745\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2849\" data-end=\"2876\"\u003e\n\u003ctr data-start=\"2849\" data-end=\"2876\"\u003e\n\u003cth data-start=\"2849\" data-end=\"2865\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2865\" data-end=\"2876\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2887\" data-end=\"3745\"\u003e\n\u003ctr data-start=\"2887\" data-end=\"2914\"\u003e\n\u003ctd data-start=\"2887\" data-end=\"2899\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2889\" data-end=\"2898\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2899\" data-end=\"2914\" data-col-size=\"sm\"\u003eFXFSQ63ARV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2915\" data-end=\"2965\"\u003e\n\u003ctd data-start=\"2915\" data-end=\"2934\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2917\" data-end=\"2933\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2934\" data-end=\"2965\" data-col-size=\"sm\"\u003e1-phase, 220–240V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2966\" data-end=\"3014\"\u003e\n\u003ctd data-start=\"2966\" data-end=\"2989\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2968\" data-end=\"2988\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2989\" data-end=\"3014\" data-col-size=\"sm\"\u003e24,200 Btu\/h \/ 7.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3015\" data-end=\"3063\"\u003e\n\u003ctd data-start=\"3015\" data-end=\"3038\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3017\" data-end=\"3037\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3038\" data-end=\"3063\" data-col-size=\"sm\"\u003e27,300 Btu\/h \/ 8.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3064\" data-end=\"3103\"\u003e\n\u003ctd data-start=\"3064\" data-end=\"3077\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3066\" data-end=\"3076\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3077\" data-end=\"3103\" data-col-size=\"sm\"\u003eGalvanized steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3104\" data-end=\"3170\"\u003e\n\u003ctd data-start=\"3104\" data-end=\"3143\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3106\" data-end=\"3142\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3143\" data-end=\"3170\" data-col-size=\"sm\"\u003e23.5 \/ 20 \/ 13.5 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3171\" data-end=\"3233\"\u003e\n\u003ctd data-start=\"3171\" data-end=\"3210\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3173\" data-end=\"3209\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3210\" data-end=\"3233\" data-col-size=\"sm\"\u003e830 \/ 706 \/ 477 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3234\" data-end=\"3296\"\u003e\n\u003ctd data-start=\"3234\" data-end=\"3272\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3236\" data-end=\"3271\"\u003eSound Level High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3272\" data-end=\"3296\" data-col-size=\"sm\"\u003e38 \/ 34.5 \/ 27 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3297\" data-end=\"3346\"\u003e\n\u003ctd data-start=\"3297\" data-end=\"3324\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3299\" data-end=\"3323\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3324\" data-end=\"3346\" data-col-size=\"sm\"\u003e256 × 840 × 840 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3347\" data-end=\"3377\"\u003e\n\u003ctd data-start=\"3347\" data-end=\"3368\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3349\" data-end=\"3367\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3368\" data-end=\"3377\" data-col-size=\"sm\"\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3378\" data-end=\"3423\"\u003e\n\u003ctd data-start=\"3378\" data-end=\"3407\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3380\" data-end=\"3406\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3407\" data-end=\"3423\" data-col-size=\"sm\"\u003e9.5 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3424\" data-end=\"3467\"\u003e\n\u003ctd data-start=\"3424\" data-end=\"3450\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3426\" data-end=\"3449\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3450\" data-end=\"3467\" data-col-size=\"sm\"\u003e15.9 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3468\" data-end=\"3507\"\u003e\n\u003ctd data-start=\"3468\" data-end=\"3491\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3470\" data-end=\"3490\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3491\" data-end=\"3507\" data-col-size=\"sm\"\u003eDia. 26 hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3508\" data-end=\"3563\"\u003e\n\u003ctd data-start=\"3508\" data-end=\"3535\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3510\" data-end=\"3534\"\u003eStandard Panel Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3535\" data-end=\"3563\" data-col-size=\"sm\"\u003eBYCQ125EAF9, Fresh White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3564\" data-end=\"3618\"\u003e\n\u003ctd data-start=\"3564\" data-end=\"3597\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3566\" data-end=\"3596\"\u003ePanel Dimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3597\" data-end=\"3618\" data-col-size=\"sm\"\u003e50 × 950 × 950 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3619\" data-end=\"3648\"\u003e\n\u003ctd data-start=\"3619\" data-end=\"3638\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3621\" data-end=\"3637\"\u003ePanel Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3638\" data-end=\"3648\" data-col-size=\"sm\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3649\" data-end=\"3681\"\u003e\n\u003ctd data-start=\"3649\" data-end=\"3671\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3651\" data-end=\"3670\"\u003eDrain Pump Lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3671\" data-end=\"3681\" data-col-size=\"sm\"\u003e850 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3682\" data-end=\"3745\"\u003e\n\u003ctd data-start=\"3682\" data-end=\"3706\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3684\" data-end=\"3705\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3706\" data-end=\"3745\" data-col-size=\"sm\"\u003eCeiling mounted cassette round flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3747\" data-end=\"3750\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3752\" data-end=\"3772\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3774\" data-end=\"4451\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3774\" data-end=\"3804\"\u003e\n\u003ctr data-start=\"3774\" data-end=\"3804\"\u003e\n\u003cth data-start=\"3774\" data-end=\"3793\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3793\" data-end=\"3804\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3815\" data-end=\"4451\"\u003e\n\u003ctr data-start=\"3815\" data-end=\"3927\"\u003e\n\u003ctd data-start=\"3815\" data-end=\"3829\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3817\" data-end=\"3828\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3829\" data-end=\"3927\" data-col-size=\"md\"\u003eHelps provide balanced airflow for desks, workstations, meeting areas, and zones near windows.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3928\" data-end=\"4039\"\u003e\n\u003ctd data-start=\"3928\" data-end=\"3946\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3930\" data-end=\"3945\"\u003eRestaurants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3946\" data-end=\"4039\" data-col-size=\"md\"\u003eSuitable for dining spaces where even comfort is required across different seating areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4040\" data-end=\"4149\"\u003e\n\u003ctd data-start=\"4040\" data-end=\"4059\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4042\" data-end=\"4058\"\u003eRetail Shops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4059\" data-end=\"4149\" data-col-size=\"md\"\u003eProvides comfortable cooling for customer areas, counters, and product display spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4150\" data-end=\"4237\"\u003e\n\u003ctd data-start=\"4150\" data-end=\"4166\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4152\" data-end=\"4165\"\u003eShowrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4166\" data-end=\"4237\" data-col-size=\"md\"\u003eHelps maintain consistent comfort across open commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4238\" data-end=\"4330\"\u003e\n\u003ctd data-start=\"4238\" data-end=\"4258\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4240\" data-end=\"4257\"\u003eMeeting Rooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4258\" data-end=\"4330\" data-col-size=\"md\"\u003eIndividual airflow settings help reduce direct airflow on occupants.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4331\" data-end=\"4451\"\u003e\n\u003ctd data-start=\"4331\" data-end=\"4358\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4333\" data-end=\"4357\"\u003eCommercial Interiors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4358\" data-end=\"4451\" data-col-size=\"md\"\u003eIdeal for ceiling cassette VRV applications requiring flexible and even air distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4453\" data-end=\"4456\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4458\" data-end=\"4474\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4476\" data-end=\"4994\"\u003e\n\u003cli data-section-id=\"jnu00p\" data-start=\"4476\" data-end=\"4532\"\u003eEfficient \u003cstrong data-start=\"4488\" data-end=\"4532\"\u003eVRV ceiling mounted cassette indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vxde8t\" data-start=\"4533\" data-end=\"4580\"\u003eCooling capacity of \u003cstrong data-start=\"4555\" data-end=\"4580\"\u003e7.1 kW \/ 24,200 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p3slxi\" data-start=\"4581\" data-end=\"4628\"\u003eHeating capacity of \u003cstrong data-start=\"4603\" data-end=\"4628\"\u003e8.0 kW \/ 27,300 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qlbvxb\" data-start=\"4629\" data-end=\"4683\"\u003e\n\u003cstrong data-start=\"4631\" data-end=\"4657\"\u003e360° all-round airflow\u003c\/strong\u003e for improved room comfort\u003c\/li\u003e\n\u003cli data-section-id=\"gjinmg\" data-start=\"4684\" data-end=\"4739\"\u003eCirculation airflow helps cool the entire room evenly\u003c\/li\u003e\n\u003cli data-section-id=\"3f1vm1\" data-start=\"4740\" data-end=\"4784\"\u003eIndividual airflow control for each outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1hz8nbh\" data-start=\"4785\" data-end=\"4833\"\u003eNew wide flap design improves airflow coverage\u003c\/li\u003e\n\u003cli data-section-id=\"1itzf8d\" data-start=\"4834\" data-end=\"4871\"\u003eHelps reduce ceiling dirt and grime\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4f8\" data-start=\"4872\" data-end=\"4914\"\u003eBuilt-in drain pump with \u003cstrong data-start=\"4899\" data-end=\"4914\"\u003e850 mm lift\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"196rmyp\" data-start=\"4915\" data-end=\"4994\"\u003eSuitable for offices, restaurants, shops, showrooms, and commercial spaces ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47830296527084,"sku":null,"price":4034.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606241011-Copy_3_-Copy.jpg?v=1782465985","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-cassette-splits-for-vrv-systems-2-0-ton-7-0-kw-2-6-hp-24-000-btu-h-fxfsq63arv1-black","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}