{"product_id":"daikin-ducted-split-air-conditioner-4-0-ton-14-0-kw-5-3-hp-48-000-btu-h-fdmrn50av1ku-rr50ay1ku","title":"Daikin Ducted Split Air Conditioner 4.0 Ton 14.0 kW 5.3 HP 48,000 Btu\/h FDMRN50AV1KU \/ RR50AY1KU","description":"\u003cp data-start=\"171\" data-end=\"457\"\u003eThe \u003cstrong data-start=\"175\" data-end=\"210\"\u003eDaikin FDMRN50AV1KU \/ RR50AY1KU\u003c\/strong\u003e is designed to provide \u003cstrong data-start=\"234\" data-end=\"279\"\u003epowerful, efficient, and discreet cooling\u003c\/strong\u003e for residential and commercial spaces. The indoor unit is concealed within the ceiling, giving the room a clean interior look while delivering comfortable airflow through ducts.\u003c\/p\u003e\n\u003chr data-start=\"459\" data-end=\"462\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"464\" data-end=\"479\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"481\" data-end=\"1018\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"481\" data-end=\"502\"\u003e\n\u003ctr data-start=\"481\" data-end=\"502\"\u003e\n\u003cth data-start=\"481\" data-end=\"491\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"491\" data-end=\"502\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"513\" data-end=\"1018\"\u003e\n\u003ctr data-start=\"513\" data-end=\"535\"\u003e\n\u003ctd data-start=\"513\" data-end=\"525\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"515\" data-end=\"524\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"525\" data-end=\"535\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"536\" data-end=\"565\"\u003e\n\u003ctd data-start=\"536\" data-end=\"549\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"538\" data-end=\"548\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"549\" data-end=\"565\" data-col-size=\"md\"\u003eFDMRN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"566\" data-end=\"601\"\u003e\n\u003ctd data-start=\"566\" data-end=\"585\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"568\" data-end=\"584\"\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"585\" data-end=\"601\" data-col-size=\"md\"\u003eFDMRN50AV1KU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"602\" data-end=\"635\"\u003e\n\u003ctd data-start=\"602\" data-end=\"622\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"604\" data-end=\"621\"\u003eOutdoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"622\" data-end=\"635\" data-col-size=\"md\"\u003eRR50AY1KU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"636\" data-end=\"688\"\u003e\n\u003ctd data-start=\"636\" data-end=\"655\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"638\" data-end=\"654\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"655\" data-end=\"688\" data-col-size=\"md\"\u003eConcealed ceiling \/ ducted AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"689\" data-end=\"724\"\u003e\n\u003ctd data-start=\"689\" data-end=\"708\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"691\" data-end=\"707\"\u003eCooling Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"708\" data-end=\"724\" data-col-size=\"md\"\u003eCooling only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"725\" data-end=\"753\"\u003e\n\u003ctd data-start=\"725\" data-end=\"743\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"727\" data-end=\"742\"\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"743\" data-end=\"753\" data-col-size=\"md\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"754\" data-end=\"812\"\u003e\n\u003ctd data-start=\"754\" data-end=\"778\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"756\" data-end=\"777\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"778\" data-end=\"812\" data-col-size=\"md\"\u003eConcealed ceiling installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"813\" data-end=\"856\"\u003e\n\u003ctd data-start=\"813\" data-end=\"835\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"815\" data-end=\"834\"\u003eCompressor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"835\" data-end=\"856\" data-col-size=\"md\"\u003eScroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"857\" data-end=\"940\"\u003e\n\u003ctd data-start=\"857\" data-end=\"880\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"859\" data-end=\"879\"\u003eMain Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"880\" data-end=\"940\" data-col-size=\"md\"\u003eHomes, offices, villas, hotels, and commercial interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"941\" data-end=\"1018\"\u003e\n\u003ctd data-start=\"941\" data-end=\"960\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"943\" data-end=\"959\"\u003eMain Benefit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"960\" data-end=\"1018\" data-col-size=\"md\"\u003eInvisible cooling with strong and reliable performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1020\" data-end=\"1023\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1025\" data-end=\"1044\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1046\" data-end=\"2313\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1046\" data-end=\"1071\"\u003e\n\u003ctr data-start=\"1046\" data-end=\"1071\"\u003e\n\u003cth data-start=\"1046\" data-end=\"1056\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1056\" data-end=\"1071\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1082\" data-end=\"2313\"\u003e\n\u003ctr data-start=\"1082\" data-end=\"1194\"\u003e\n\u003ctd data-start=\"1082\" data-end=\"1113\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1084\" data-end=\"1112\"\u003eConcealed Ceiling Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1113\" data-end=\"1194\" data-col-size=\"md\"\u003eInstalled above the ceiling for a clean, invisible air-conditioning solution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1195\" data-end=\"1284\"\u003e\n\u003ctd data-start=\"1195\" data-end=\"1220\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1197\" data-end=\"1219\"\u003eR-410A Refrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1220\" data-end=\"1284\" data-col-size=\"md\"\u003eUses R-410A refrigerant with zero ozone depletion potential.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1285\" data-end=\"1388\"\u003e\n\u003ctd data-start=\"1285\" data-end=\"1308\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1307\"\u003ePowerful Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1308\" data-end=\"1388\"\u003eProvides strong cooling performance even when outdoor temperatures are high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1389\" data-end=\"1495\"\u003e\n\u003ctd data-start=\"1389\" data-end=\"1419\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1391\" data-end=\"1418\"\u003eEnergy Saving Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1419\" data-end=\"1495\"\u003eDesigned for efficient operation to help reduce electricity consumption.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1496\" data-end=\"1598\"\u003e\n\u003ctd data-start=\"1496\" data-end=\"1526\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1498\" data-end=\"1525\"\u003eOptimal Cooling Comfort\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1526\" data-end=\"1598\" data-col-size=\"md\"\u003eIncludes comfort modes such as Turbo Mode, Sleep Mode, and Dry Mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1599\" data-end=\"1692\"\u003e\n\u003ctd data-start=\"1599\" data-end=\"1629\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1601\" data-end=\"1628\"\u003eWhisper Quiet Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1629\" data-end=\"1692\"\u003eIndoor sound level can be reduced for quieter room comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1693\" data-end=\"1793\"\u003e\n\u003ctd data-start=\"1693\" data-end=\"1723\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1695\" data-end=\"1722\"\u003eHigh Design Flexibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1723\" data-end=\"1793\" data-col-size=\"md\"\u003eWide external static pressure range supports flexible duct design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1794\" data-end=\"1894\"\u003e\n\u003ctd data-start=\"1794\" data-end=\"1818\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1796\" data-end=\"1817\"\u003eEasy Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1818\" data-end=\"1894\" data-col-size=\"md\"\u003eOutdoor unit can be mounted on a roof or placed against an outside wall.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1895\" data-end=\"2002\"\u003e\n\u003ctd data-start=\"1895\" data-end=\"1935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1897\" data-end=\"1934\"\u003eDouble Protection Drainage System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1935\" data-end=\"2002\"\u003eReinforced drainage protection helps reduce water leakage risk.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2003\" data-end=\"2107\"\u003e\n\u003ctd data-start=\"2003\" data-end=\"2044\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2005\" data-end=\"2043\"\u003eStandard Anti-Corrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2044\" data-end=\"2107\"\u003eHelps protect important components for longer service life.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2108\" data-end=\"2222\"\u003e\n\u003ctd data-start=\"2108\" data-end=\"2134\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2110\" data-end=\"2133\"\u003eAuto Random Restart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2134\" data-end=\"2222\"\u003eAutomatically restarts after power failure while helping prevent sudden power surge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2223\" data-end=\"2313\"\u003e\n\u003ctd data-start=\"2223\" data-end=\"2242\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2225\" data-end=\"2241\"\u003eLong Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2242\" data-end=\"2313\"\u003eDesigned to deliver airflow over longer distances for large spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2315\" data-end=\"2318\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2320\" data-end=\"2343\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2345\" data-end=\"3044\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2345\" data-end=\"2372\"\u003e\n\u003ctr data-start=\"2345\" data-end=\"2372\"\u003e\n\u003cth data-start=\"2345\" data-end=\"2361\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2361\" data-end=\"2372\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2383\" data-end=\"3044\"\u003e\n\u003ctr data-start=\"2383\" data-end=\"2418\"\u003e\n\u003ctd data-start=\"2383\" data-end=\"2402\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2385\" data-end=\"2401\"\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2402\" data-end=\"2418\" data-col-size=\"sm\"\u003eFDMRN50AV1KU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2419\" data-end=\"2452\"\u003e\n\u003ctd data-start=\"2419\" data-end=\"2439\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2421\" data-end=\"2438\"\u003eOutdoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2439\" data-end=\"2452\" data-col-size=\"sm\"\u003eRR50AY1KU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2453\" data-end=\"2497\"\u003e\n\u003ctd data-start=\"2453\" data-end=\"2472\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2455\" data-end=\"2471\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2472\" data-end=\"2497\" data-col-size=\"sm\"\u003e380–415V \/ 3Ph \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2498\" data-end=\"2551\"\u003e\n\u003ctd data-start=\"2498\" data-end=\"2524\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2500\" data-end=\"2523\"\u003eCooling Capacity T1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2524\" data-end=\"2551\"\u003e48,000 Btu\/h \/ 14.07 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2552\" data-end=\"2605\"\u003e\n\u003ctd data-start=\"2552\" data-end=\"2578\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2554\" data-end=\"2577\"\u003eCooling Capacity T3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2578\" data-end=\"2605\" data-col-size=\"sm\"\u003e43,600 Btu\/h \/ 12.78 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2606\" data-end=\"2636\"\u003e\n\u003ctd data-start=\"2606\" data-end=\"2619\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2608\" data-end=\"2618\"\u003eEER T1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2619\" data-end=\"2636\" data-col-size=\"sm\"\u003e11.62 Btu\/h\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2637\" data-end=\"2666\"\u003e\n\u003ctd data-start=\"2637\" data-end=\"2650\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2639\" data-end=\"2649\"\u003eEER T3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2666\" data-col-size=\"sm\"\u003e8.55 Btu\/h\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2667\" data-end=\"2706\"\u003e\n\u003ctd data-start=\"2667\" data-end=\"2692\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2669\" data-end=\"2691\"\u003eESP Range High Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2692\" data-end=\"2706\"\u003e50 \/ 75 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2707\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2707\" data-end=\"2728\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2709\" data-end=\"2727\"\u003eIndoor Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2728\" data-end=\"2757\" data-col-size=\"sm\"\u003e1,726 \/ 1,441 \/ 1,300 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2805\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2783\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2760\" data-end=\"2782\"\u003eIndoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2783\" data-end=\"2805\" data-col-size=\"sm\"\u003e46 \/ 44 \/ 41 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2806\" data-end=\"2854\"\u003e\n\u003ctd data-start=\"2806\" data-end=\"2830\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2808\" data-end=\"2829\"\u003eIndoor Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2830\" data-end=\"2854\"\u003e378 × 1,487 × 541 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2855\" data-end=\"2888\"\u003e\n\u003ctd data-start=\"2855\" data-end=\"2878\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2857\" data-end=\"2877\"\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2878\" data-end=\"2888\" data-col-size=\"sm\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2889\" data-end=\"2921\"\u003e\n\u003ctd data-start=\"2889\" data-end=\"2911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2891\" data-end=\"2910\"\u003eCompressor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2911\" data-end=\"2921\"\u003eScroll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2922\" data-end=\"2956\"\u003e\n\u003ctd data-start=\"2922\" data-end=\"2948\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2924\" data-end=\"2947\"\u003eTotal Piping Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2948\" data-end=\"2956\" data-col-size=\"sm\"\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2957\" data-end=\"2994\"\u003e\n\u003ctd data-start=\"2957\" data-end=\"2986\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2959\" data-end=\"2985\"\u003eVertical Piping Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2986\" data-end=\"2994\"\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2995\" data-end=\"3044\"\u003e\n\u003ctd data-start=\"2995\" data-end=\"3029\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2997\" data-end=\"3028\"\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3029\" data-end=\"3044\"\u003e19°C – 54°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3046\" data-end=\"3049\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3051\" data-end=\"3071\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3073\" data-end=\"3575\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3073\" data-end=\"3103\"\u003e\n\u003ctr data-start=\"3073\" data-end=\"3103\"\u003e\n\u003cth data-start=\"3073\" data-end=\"3092\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3092\" data-end=\"3103\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3114\" data-end=\"3575\"\u003e\n\u003ctr data-start=\"3114\" data-end=\"3190\"\u003e\n\u003ctd data-start=\"3114\" data-end=\"3127\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3116\" data-end=\"3126\"\u003eVillas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3127\" data-end=\"3190\" data-col-size=\"md\"\u003eIdeal for discreet cooling in large rooms and living spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3191\" data-end=\"3263\"\u003e\n\u003ctd data-start=\"3191\" data-end=\"3209\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3193\" data-end=\"3208\"\u003eHotel Rooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3209\" data-end=\"3263\"\u003eHidden AC installation for premium interior design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3264\" data-end=\"3339\"\u003e\n\u003ctd data-start=\"3264\" data-end=\"3278\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3266\" data-end=\"3277\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3278\" data-end=\"3339\"\u003eSuitable for ducted cooling with clean ceiling appearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3340\" data-end=\"3424\"\u003e\n\u003ctd data-start=\"3340\" data-end=\"3360\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3342\" data-end=\"3359\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3360\" data-end=\"3424\" data-col-size=\"md\"\u003eProvides powerful cooling without visible wall-mounted units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3425\" data-end=\"3508\"\u003e\n\u003ctd data-start=\"3425\" data-end=\"3452\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3427\" data-end=\"3451\"\u003eCommercial Interiors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3452\" data-end=\"3508\" data-col-size=\"md\"\u003eFlexible ducting and airflow for larger indoor areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3509\" data-end=\"3575\"\u003e\n\u003ctd data-start=\"3509\" data-end=\"3530\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3511\" data-end=\"3529\"\u003eLarge Bedrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3530\" data-end=\"3575\" data-col-size=\"md\"\u003eQuiet and comfortable cooling performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3577\" data-end=\"3580\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"3582\" data-end=\"3598\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"3600\" data-end=\"4155\"\u003e\n\u003cli data-section-id=\"qyfx9g\" data-start=\"3600\" data-end=\"3662\"\u003eConcealed ceiling design keeps interiors clean and elegant\u003c\/li\u003e\n\u003cli data-section-id=\"u6zkgp\" data-start=\"3663\" data-end=\"3727\"\u003eStrong cooling capacity for large rooms and commercial areas\u003c\/li\u003e\n\u003cli data-section-id=\"xg6l5z\" data-start=\"3728\" data-end=\"3786\"\u003eR-410A refrigerant with zero ozone depletion potential\u003c\/li\u003e\n\u003cli data-section-id=\"1l5e8kk\" data-start=\"3787\" data-end=\"3841\"\u003eEfficient operation helps reduce electricity usage\u003c\/li\u003e\n\u003cli data-section-id=\"15p4id\" data-start=\"3842\" data-end=\"3893\"\u003eQuiet indoor performance for comfortable spaces\u003c\/li\u003e\n\u003cli data-section-id=\"i3y7ga\" data-start=\"3894\" data-end=\"3938\"\u003eFlexible duct design with adjustable ESP\u003c\/li\u003e\n\u003cli data-section-id=\"2yq7vn\" data-start=\"3939\" data-end=\"3992\"\u003eDouble drain pan protection against water leakage\u003c\/li\u003e\n\u003cli data-section-id=\"5tqj8r\" data-start=\"3993\" data-end=\"4044\"\u003eAnti-corrosion protection for longer durability\u003c\/li\u003e\n\u003cli data-section-id=\"1e4fl2o\" data-start=\"4045\" data-end=\"4088\"\u003eAuto random restart after power failure\u003c\/li\u003e\n\u003cli data-section-id=\"tr8zea\" data-start=\"4089\" data-end=\"4155\"\u003eSuitable for homes, offices, hotels, villas, and retail spaces\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47781102584044,"sku":null,"price":9749.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Daikin_FDMRN_Indoor.webp?v=1782284026","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-ducted-split-air-conditioner-4-0-ton-14-0-kw-5-3-hp-48-000-btu-h-fdmrn50av1ku-rr50ay1ku","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}