{"product_id":"daikin-ducted-splits-for-vrv-systems-2-0-ton-7-0-kw-2-6-hp-24-000-btu-h-fxmq63pbv1","title":"Daikin Ducted Splits for VRV Systems 2.0 Ton 7.0 kW 2.6 HP 24,000 Btu\/h FXMQ63PBV1","description":"\u003cp data-start=\"177\" data-end=\"652\"\u003eThe \u003cstrong data-start=\"181\" data-end=\"202\"\u003eDaikin FXMQ63PBV1\u003c\/strong\u003e is a high static concealed ceiling ducted indoor unit designed for flexible duct installation, efficient airflow control, and quiet comfort in residential and commercial spaces. With \u003cstrong data-start=\"386\" data-end=\"413\"\u003e7.1 kW cooling capacity\u003c\/strong\u003e, \u003cstrong data-start=\"415\" data-end=\"442\"\u003e8.0 kW heating capacity\u003c\/strong\u003e, and external static pressure support up to \u003cstrong data-start=\"487\" data-end=\"497\"\u003e200 Pa\u003c\/strong\u003e, it is suitable for villas, offices, restaurants, retail shops, showrooms, hotels, and commercial interiors requiring concealed ducted AC installation. ❄️\u003c\/p\u003e\n\u003chr data-start=\"654\" data-end=\"657\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"659\" data-end=\"674\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"676\" data-end=\"1316\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"676\" data-end=\"701\"\u003e\n\u003ctr data-start=\"676\" data-end=\"701\"\u003e\n\u003cth data-start=\"676\" data-end=\"686\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"686\" data-end=\"701\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"712\" data-end=\"1316\"\u003e\n\u003ctr data-start=\"712\" data-end=\"734\"\u003e\n\u003ctd data-start=\"712\" data-end=\"724\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"714\" data-end=\"723\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"724\" data-end=\"734\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"735\" data-end=\"761\"\u003e\n\u003ctd data-start=\"735\" data-end=\"747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"737\" data-end=\"746\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"747\" data-end=\"761\" data-col-size=\"md\"\u003eFXMQ63PBV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"762\" data-end=\"788\"\u003e\n\u003ctd data-start=\"762\" data-end=\"775\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"764\" data-end=\"774\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"775\" data-end=\"788\" data-col-size=\"md\"\u003eFXMQ-PBV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"789\" data-end=\"850\"\u003e\n\u003ctd data-start=\"789\" data-end=\"808\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"791\" data-end=\"807\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"808\" data-end=\"850\" data-col-size=\"md\"\u003eVRV concealed ceiling duct indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"851\" data-end=\"913\"\u003e\n\u003ctd data-start=\"851\" data-end=\"875\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"853\" data-end=\"874\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"875\" data-end=\"913\" data-col-size=\"md\"\u003eHigh static concealed ceiling duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"914\" data-end=\"962\"\u003e\n\u003ctd data-start=\"914\" data-end=\"937\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"916\" data-end=\"936\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"937\" data-end=\"962\" data-col-size=\"md\"\u003e7.1 kW \/ 24,200 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"963\" data-end=\"1011\"\u003e\n\u003ctd data-start=\"963\" data-end=\"986\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"965\" data-end=\"985\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"986\" data-end=\"1011\" data-col-size=\"md\"\u003e8.0 kW \/ 27,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1012\" data-end=\"1062\"\u003e\n\u003ctd data-start=\"1012\" data-end=\"1031\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1014\" data-end=\"1030\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1031\" data-end=\"1062\" data-col-size=\"md\"\u003e1 phase, 220–240V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1063\" data-end=\"1107\"\u003e\n\u003ctd data-start=\"1063\" data-end=\"1094\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1093\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1094\" data-end=\"1107\" data-col-size=\"md\"\u003e50–200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1108\" data-end=\"1165\"\u003e\n\u003ctd data-start=\"1108\" data-end=\"1125\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1110\" data-end=\"1124\"\u003eDrain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1125\" data-end=\"1165\" data-col-size=\"md\"\u003eStandard drain pump with 700 mm lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1166\" data-end=\"1205\"\u003e\n\u003ctd data-start=\"1166\" data-end=\"1179\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1178\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1179\" data-end=\"1205\" data-col-size=\"md\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1206\" data-end=\"1316\"\u003e\n\u003ctd data-start=\"1206\" data-end=\"1224\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1223\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1224\" data-end=\"1316\" data-col-size=\"md\"\u003eVillas, offices, restaurants, hotels, showrooms, retail spaces, and commercial interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1318\" data-end=\"1321\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1323\" data-end=\"1342\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1344\" data-end=\"3083\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1344\" data-end=\"1365\"\u003e\n\u003ctr data-start=\"1344\" data-end=\"1365\"\u003e\n\u003cth data-start=\"1344\" data-end=\"1354\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1354\" data-end=\"1365\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1376\" data-end=\"3083\"\u003e\n\u003ctr data-start=\"1376\" data-end=\"1512\"\u003e\n\u003ctd data-start=\"1376\" data-end=\"1410\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1378\" data-end=\"1409\"\u003eHigh Static Pressure Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1410\" data-end=\"1512\" data-col-size=\"lg\"\u003eMiddle and high static pressure capability allows flexible duct design for different room layouts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1513\" data-end=\"1654\"\u003e\n\u003ctd data-start=\"1513\" data-end=\"1532\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1531\"\u003eDC Fan Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1532\" data-end=\"1654\" data-col-size=\"lg\"\u003eThe adopted DC fan motor improves efficiency and helps reduce energy consumption compared with conventional AC motors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1655\" data-end=\"1783\"\u003e\n\u003ctd data-start=\"1655\" data-end=\"1682\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1657\" data-end=\"1681\"\u003eFlexible Duct Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1682\" data-end=\"1783\" data-col-size=\"lg\"\u003eExternal static pressure range supports duct layouts for residential and commercial applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1784\" data-end=\"1935\"\u003e\n\u003ctd data-start=\"1784\" data-end=\"1821\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1786\" data-end=\"1820\"\u003eConcealed Ceiling Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1821\" data-end=\"1935\" data-col-size=\"lg\"\u003eThe unit is hidden above the ceiling, keeping interiors clean while supplying air through ducts and diffusers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1936\" data-end=\"2046\"\u003e\n\u003ctd data-start=\"1936\" data-end=\"1957\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1938\" data-end=\"1956\"\u003eCompact Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1957\" data-end=\"2046\" data-col-size=\"lg\"\u003eUnit height is only \u003cstrong data-start=\"1979\" data-end=\"1989\"\u003e300 mm\u003c\/strong\u003e, making installation easier in limited ceiling spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2047\" data-end=\"2176\"\u003e\n\u003ctd data-start=\"2047\" data-end=\"2073\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2049\" data-end=\"2072\"\u003eStandard Drain Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2073\" data-end=\"2176\" data-col-size=\"lg\"\u003eBuilt-in drain pump with \u003cstrong data-start=\"2100\" data-end=\"2115\"\u003e700 mm lift\u003c\/strong\u003e improves installation flexibility and condensate drainage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2177\" data-end=\"2311\"\u003e\n\u003ctd data-start=\"2177\" data-end=\"2208\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2179\" data-end=\"2207\"\u003eImproved Airflow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2208\" data-end=\"2311\" data-col-size=\"lg\"\u003eAirflow rate control has been improved from 2-step to 3-step control for better comfort adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2312\" data-end=\"2454\"\u003e\n\u003ctd data-start=\"2312\" data-end=\"2347\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2314\" data-end=\"2346\"\u003eAutomatic Airflow Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2347\" data-end=\"2454\" data-col-size=\"lg\"\u003eAutomatically selects the most suitable fan curve to achieve nominal airflow within approximately ±10%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2455\" data-end=\"2571\"\u003e\n\u003ctd data-start=\"2455\" data-end=\"2490\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2457\" data-end=\"2489\"\u003eRemote Controller Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2490\" data-end=\"2571\" data-col-size=\"lg\"\u003eAirflow rate can be adjusted using a remote controller during test operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2572\" data-end=\"2702\"\u003e\n\u003ctd data-start=\"2572\" data-end=\"2598\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2574\" data-end=\"2597\"\u003eLow Operation Sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2598\" data-end=\"2702\" data-col-size=\"lg\"\u003eDesigned for quiet ducted operation, suitable for offices, villas, hotels, and commercial interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2703\" data-end=\"2795\"\u003e\n\u003ctd data-start=\"2703\" data-end=\"2726\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2705\" data-end=\"2725\"\u003eEasy Maintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2726\" data-end=\"2795\" data-col-size=\"lg\"\u003eDrain pan can be detached for easier cleaning and service access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2796\" data-end=\"2948\"\u003e\n\u003ctd data-start=\"2796\" data-end=\"2832\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2798\" data-end=\"2831\"\u003eAntibacterial Drain Treatment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2832\" data-end=\"2948\" data-col-size=\"lg\"\u003eSilver ion antibacterial treatment helps prevent slime, mould, and bacteria that can cause blockages and odours.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2949\" data-end=\"3083\"\u003e\n\u003ctd data-start=\"2949\" data-end=\"2982\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2951\" data-end=\"2981\"\u003eEnergy Efficient Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2982\" data-end=\"3083\" data-col-size=\"lg\"\u003eDC fan motor design helps reduce energy consumption while maintaining strong airflow performance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3085\" data-end=\"3088\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"3090\" data-end=\"3113\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3115\" data-end=\"4043\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3115\" data-end=\"3142\"\u003e\n\u003ctr data-start=\"3115\" data-end=\"3142\"\u003e\n\u003cth data-start=\"3115\" data-end=\"3131\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3131\" data-end=\"3142\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3153\" data-end=\"4043\"\u003e\n\u003ctr data-start=\"3153\" data-end=\"3179\"\u003e\n\u003ctd data-start=\"3153\" data-end=\"3165\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3155\" data-end=\"3164\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3165\" data-end=\"3179\" data-col-size=\"md\"\u003eFXMQ63PBV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3180\" data-end=\"3230\"\u003e\n\u003ctd data-start=\"3180\" data-end=\"3199\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3182\" data-end=\"3198\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3199\" data-end=\"3230\" data-col-size=\"md\"\u003e1 phase, 220–240V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3231\" data-end=\"3270\"\u003e\n\u003ctd data-start=\"3231\" data-end=\"3254\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3233\" data-end=\"3253\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3254\" data-end=\"3270\" data-col-size=\"md\"\u003e24,200 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3271\" data-end=\"3304\"\u003e\n\u003ctd data-start=\"3271\" data-end=\"3294\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3273\" data-end=\"3293\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3294\" data-end=\"3304\" data-col-size=\"md\"\u003e7.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3305\" data-end=\"3344\"\u003e\n\u003ctd data-start=\"3305\" data-end=\"3328\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3307\" data-end=\"3327\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3328\" data-end=\"3344\" data-col-size=\"md\"\u003e27,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3345\" data-end=\"3378\"\u003e\n\u003ctd data-start=\"3345\" data-end=\"3368\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3347\" data-end=\"3367\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3368\" data-end=\"3378\" data-col-size=\"md\"\u003e8.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3379\" data-end=\"3418\"\u003e\n\u003ctd data-start=\"3379\" data-end=\"3392\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3381\" data-end=\"3391\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3392\" data-end=\"3418\" data-col-size=\"md\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3419\" data-end=\"3485\"\u003e\n\u003ctd data-start=\"3419\" data-end=\"3458\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3421\" data-end=\"3457\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3458\" data-end=\"3485\" data-col-size=\"md\"\u003e19.5 \/ 17.5 \/ 16 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3486\" data-end=\"3548\"\u003e\n\u003ctd data-start=\"3486\" data-end=\"3525\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3488\" data-end=\"3524\"\u003eAirflow Rate High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3525\" data-end=\"3548\" data-col-size=\"md\"\u003e688 \/ 618 \/ 565 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3549\" data-end=\"3593\"\u003e\n\u003ctd data-start=\"3549\" data-end=\"3580\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3551\" data-end=\"3579\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3580\" data-end=\"3593\" data-col-size=\"md\"\u003e50–200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3594\" data-end=\"3654\"\u003e\n\u003ctd data-start=\"3594\" data-end=\"3632\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3596\" data-end=\"3631\"\u003eSound Level High \/ Medium \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3632\" data-end=\"3654\" data-col-size=\"md\"\u003e42 \/ 40 \/ 38 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3655\" data-end=\"3706\"\u003e\n\u003ctd data-start=\"3655\" data-end=\"3682\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3657\" data-end=\"3681\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3682\" data-end=\"3706\" data-col-size=\"md\"\u003e300 × 1,000 × 700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3707\" data-end=\"3737\"\u003e\n\u003ctd data-start=\"3707\" data-end=\"3728\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3709\" data-end=\"3727\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3728\" data-end=\"3737\" data-col-size=\"md\"\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3738\" data-end=\"3785\"\u003e\n\u003ctd data-start=\"3738\" data-end=\"3767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3740\" data-end=\"3766\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3767\" data-end=\"3785\" data-col-size=\"md\"\u003eØ 9.5 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3786\" data-end=\"3831\"\u003e\n\u003ctd data-start=\"3786\" data-end=\"3812\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3788\" data-end=\"3811\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3812\" data-end=\"3831\" data-col-size=\"md\"\u003eØ 15.9 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3832\" data-end=\"3906\"\u003e\n\u003ctd data-start=\"3832\" data-end=\"3855\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3834\" data-end=\"3854\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3855\" data-end=\"3906\" data-col-size=\"md\"\u003eVP25, External Dia. 32 mm \/ Internal Dia. 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3907\" data-end=\"3939\"\u003e\n\u003ctd data-start=\"3907\" data-end=\"3929\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3909\" data-end=\"3928\"\u003eDrain Pump Lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3929\" data-end=\"3939\" data-col-size=\"md\"\u003e700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3940\" data-end=\"4002\"\u003e\n\u003ctd data-start=\"3940\" data-end=\"3964\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3942\" data-end=\"3963\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3964\" data-end=\"4002\" data-col-size=\"md\"\u003eHigh static concealed ceiling duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4003\" data-end=\"4043\"\u003e\n\u003ctd data-start=\"4003\" data-end=\"4025\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4005\" data-end=\"4024\"\u003eAirflow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4025\" data-end=\"4043\" data-col-size=\"md\"\u003e3-step control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4045\" data-end=\"4048\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"4050\" data-end=\"4070\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4072\" data-end=\"4732\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4072\" data-end=\"4102\"\u003e\n\u003ctr data-start=\"4072\" data-end=\"4102\"\u003e\n\u003cth data-start=\"4072\" data-end=\"4091\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"4091\" data-end=\"4102\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4113\" data-end=\"4732\"\u003e\n\u003ctr data-start=\"4113\" data-end=\"4242\"\u003e\n\u003ctd data-start=\"4113\" data-end=\"4139\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4115\" data-end=\"4138\"\u003eVillas \u0026amp; Apartments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4139\" data-end=\"4242\" data-col-size=\"md\"\u003eSuitable for concealed ducted cooling in living rooms, bedrooms, and premium residential interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4243\" data-end=\"4342\"\u003e\n\u003ctd data-start=\"4243\" data-end=\"4257\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4245\" data-end=\"4256\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4257\" data-end=\"4342\" data-col-size=\"md\"\u003eIdeal for private offices, open workspaces, meeting rooms, and commercial cabins.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4343\" data-end=\"4436\"\u003e\n\u003ctd data-start=\"4343\" data-end=\"4361\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4345\" data-end=\"4360\"\u003eRestaurants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4361\" data-end=\"4436\" data-col-size=\"md\"\u003eSupports ducted air distribution across dining areas and seating zones.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4437\" data-end=\"4533\"\u003e\n\u003ctd data-start=\"4437\" data-end=\"4457\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4439\" data-end=\"4456\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4457\" data-end=\"4533\" data-col-size=\"md\"\u003eSuitable for boutiques, shops, showrooms, and customer-facing interiors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4534\" data-end=\"4622\"\u003e\n\u003ctd data-start=\"4534\" data-end=\"4547\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4536\" data-end=\"4546\"\u003eHotels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4547\" data-end=\"4622\" data-col-size=\"md\"\u003eWorks well for guest rooms, corridors, lounges, and hospitality spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4623\" data-end=\"4732\"\u003e\n\u003ctd data-start=\"4623\" data-end=\"4650\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4625\" data-end=\"4649\"\u003eCommercial Buildings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4650\" data-end=\"4732\" data-col-size=\"md\"\u003eSuitable for spaces requiring flexible duct design and concealed indoor units.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4734\" data-end=\"4737\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4739\" data-end=\"4755\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4757\" data-end=\"5355\"\u003e\n\u003cli data-section-id=\"1ib7315\" data-start=\"4757\" data-end=\"4811\"\u003eEfficient \u003cstrong data-start=\"4769\" data-end=\"4811\"\u003eVRV concealed ceiling duct indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vxde8t\" data-start=\"4812\" data-end=\"4859\"\u003eCooling capacity of \u003cstrong data-start=\"4834\" data-end=\"4859\"\u003e7.1 kW \/ 24,200 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p3slxi\" data-start=\"4860\" data-end=\"4907\"\u003eHeating capacity of \u003cstrong data-start=\"4882\" data-end=\"4907\"\u003e8.0 kW \/ 27,300 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nyq3pb\" data-start=\"4908\" data-end=\"4966\"\u003eFlexible external static pressure range up to \u003cstrong data-start=\"4956\" data-end=\"4966\"\u003e200 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y2hwh4\" data-start=\"4967\" data-end=\"5031\"\u003eCompact \u003cstrong data-start=\"4977\" data-end=\"4987\"\u003e300 mm\u003c\/strong\u003e unit height for easier ceiling installation\u003c\/li\u003e\n\u003cli data-section-id=\"1c207f2\" data-start=\"5032\" data-end=\"5074\"\u003eBuilt-in drain pump with \u003cstrong data-start=\"5059\" data-end=\"5074\"\u003e700 mm lift\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"140gg65\" data-start=\"5075\" data-end=\"5120\"\u003eDC fan motor for improved energy efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"cflp5a\" data-start=\"5121\" data-end=\"5164\"\u003e3-step airflow control for better comfort\u003c\/li\u003e\n\u003cli data-section-id=\"1om3m8g\" data-start=\"5165\" data-end=\"5204\"\u003eAutomatic airflow adjustment function\u003c\/li\u003e\n\u003cli data-section-id=\"137ouxl\" data-start=\"5205\" data-end=\"5263\"\u003eAntibacterial drain pan treatment for easier maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"jpteiy\" data-start=\"5264\" data-end=\"5355\"\u003eSuitable for villas, offices, restaurants, showrooms, hotels, and commercial interiors ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47832424251628,"sku":null,"price":4299.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606231550-Copy_5.jpg?v=1782534977","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-ducted-splits-for-vrv-systems-2-0-ton-7-0-kw-2-6-hp-24-000-btu-h-fxmq63pbv1","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}