{"product_id":"daikin-ducted-splits-for-vrv-systems-6-3-ton-22-4-kw-8-5-hp-76-400-btu-h-fxmq200nve6","title":"Daikin Ducted Splits for VRV Systems 6.3 Ton 22.4 kW 8.5 HP 76,400 Btu\/h FXMQ200NVE6","description":"\u003cp data-start=\"174\" data-end=\"610\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"178\" data-end=\"200\"\u003eDaikin FXMQ200NVE6\u003c\/strong\u003e is a high-capacity VRV ceiling mounted ducted indoor unit designed for large commercial and industrial spaces that need powerful, reliable, and concealed air conditioning. With \u003cstrong data-start=\"378\" data-end=\"406\"\u003e22.4 kW cooling capacity\u003c\/strong\u003e, \u003cstrong data-start=\"408\" data-end=\"436\"\u003e25.0 kW heating capacity\u003c\/strong\u003e, and external static pressure up to \u003cstrong data-start=\"473\" data-end=\"483\"\u003e200 Pa\u003c\/strong\u003e, it is suitable for large offices, warehouses, factories, showrooms, retail areas, and other demanding ducted applications. ❄️\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"612\" data-end=\"615\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"617\" data-end=\"632\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"634\" data-end=\"1190\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"634\" data-end=\"659\"\u003e\n\u003ctr data-start=\"634\" data-end=\"659\"\u003e\n\u003cth data-start=\"634\" data-end=\"644\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"644\" data-end=\"659\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"670\" data-end=\"1190\"\u003e\n\u003ctr data-start=\"670\" data-end=\"692\"\u003e\n\u003ctd data-start=\"670\" data-end=\"682\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"672\" data-end=\"681\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"682\" data-end=\"692\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"693\" data-end=\"720\"\u003e\n\u003ctd data-start=\"693\" data-end=\"705\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"695\" data-end=\"704\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"705\" data-end=\"720\" data-col-size=\"md\"\u003eFXMQ200NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"721\" data-end=\"747\"\u003e\n\u003ctd data-start=\"721\" data-end=\"734\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"723\" data-end=\"733\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"734\" data-end=\"747\" data-col-size=\"md\"\u003eFXMQ-NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"748\" data-end=\"793\"\u003e\n\u003ctd data-start=\"748\" data-end=\"767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"750\" data-end=\"766\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"767\" data-end=\"793\" data-col-size=\"md\"\u003eVRV ducted indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"794\" data-end=\"854\"\u003e\n\u003ctd data-start=\"794\" data-end=\"818\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"796\" data-end=\"817\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"818\" data-end=\"854\" data-col-size=\"md\"\u003eHigh static ceiling mounted duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"855\" data-end=\"904\"\u003e\n\u003ctd data-start=\"855\" data-end=\"878\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"857\" data-end=\"877\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"878\" data-end=\"904\" data-col-size=\"md\"\u003e22.4 kW \/ 76,400 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"905\" data-end=\"954\"\u003e\n\u003ctd data-start=\"905\" data-end=\"928\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"907\" data-end=\"927\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"928\" data-end=\"954\" data-col-size=\"md\"\u003e25.0 kW \/ 83,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"955\" data-end=\"998\"\u003e\n\u003ctd data-start=\"955\" data-end=\"974\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"957\" data-end=\"973\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"974\" data-end=\"998\" data-col-size=\"md\"\u003e1 phase, 230V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"999\" data-end=\"1044\"\u003e\n\u003ctd data-start=\"999\" data-end=\"1030\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1029\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1030\" data-end=\"1044\" data-col-size=\"md\"\u003e100–200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1045\" data-end=\"1084\"\u003e\n\u003ctd data-start=\"1045\" data-end=\"1058\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1047\" data-end=\"1057\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1058\" data-end=\"1084\" data-col-size=\"md\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1085\" data-end=\"1190\"\u003e\n\u003ctd data-start=\"1085\" data-end=\"1103\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1087\" data-end=\"1102\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1103\" data-end=\"1190\" data-col-size=\"md\"\u003eLarge rooms, commercial spaces, warehouses, factories, showrooms, and large offices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1192\" data-end=\"1195\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1197\" data-end=\"1216\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1218\" data-end=\"2692\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1218\" data-end=\"1239\"\u003e\n\u003ctr data-start=\"1218\" data-end=\"1239\"\u003e\n\u003cth data-start=\"1218\" data-end=\"1228\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1228\" data-end=\"1239\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1250\" data-end=\"2692\"\u003e\n\u003ctr data-start=\"1250\" data-end=\"1379\"\u003e\n\u003ctd data-start=\"1250\" data-end=\"1284\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1283\"\u003eHigh Static Pressure Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1284\" data-end=\"1379\" data-col-size=\"lg\"\u003eExternal static pressure up to \u003cstrong data-start=\"1317\" data-end=\"1327\"\u003e200 Pa\u003c\/strong\u003e supports ducted air distribution for large areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1380\" data-end=\"1507\"\u003e\n\u003ctd data-start=\"1380\" data-end=\"1408\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1382\" data-end=\"1407\"\u003eHigh Cooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1408\" data-end=\"1507\" data-col-size=\"lg\"\u003eProvides \u003cstrong data-start=\"1419\" data-end=\"1430\"\u003e22.4 kW\u003c\/strong\u003e cooling capacity, suitable for demanding commercial and industrial spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1508\" data-end=\"1610\"\u003e\n\u003ctd data-start=\"1508\" data-end=\"1540\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1510\" data-end=\"1539\"\u003ePowerful Heating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1540\" data-end=\"1610\" data-col-size=\"lg\"\u003eOffers \u003cstrong data-start=\"1549\" data-end=\"1560\"\u003e25.0 kW\u003c\/strong\u003e heating capacity for year-round indoor comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1611\" data-end=\"1728\"\u003e\n\u003ctd data-start=\"1611\" data-end=\"1638\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1613\" data-end=\"1637\"\u003eLarge Airflow Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1638\" data-end=\"1728\" data-col-size=\"lg\"\u003eHigh airflow rate helps distribute conditioned air across wide rooms and duct layouts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1729\" data-end=\"1851\"\u003e\n\u003ctd data-start=\"1729\" data-end=\"1754\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1753\"\u003eTwo-Step Fan Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1754\" data-end=\"1851\" data-col-size=\"lg\"\u003eHigh and low fan speed operation allows airflow adjustment according to comfort requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1852\" data-end=\"1999\"\u003e\n\u003ctd data-start=\"1852\" data-end=\"1888\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1854\" data-end=\"1887\"\u003eConcealed Ducted Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1888\" data-end=\"1999\" data-col-size=\"lg\"\u003eCeiling mounted ducted design keeps the indoor unit hidden while supplying air through ducts and diffusers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2000\" data-end=\"2120\"\u003e\n\u003ctd data-start=\"2000\" data-end=\"2024\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2002\" data-end=\"2023\"\u003eClean Air Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2024\" data-end=\"2120\" data-col-size=\"lg\"\u003eAir filter helps remove airborne dust particles and supports cleaner indoor air circulation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2121\" data-end=\"2216\"\u003e\n\u003ctd data-start=\"2121\" data-end=\"2141\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2123\" data-end=\"2140\"\u003eDry Programme\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2141\" data-end=\"2216\" data-col-size=\"lg\"\u003eHelps reduce humidity levels without major changes in room temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2217\" data-end=\"2329\"\u003e\n\u003ctd data-start=\"2217\" data-end=\"2247\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2219\" data-end=\"2246\"\u003eSelf-Diagnosis Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2247\" data-end=\"2329\" data-col-size=\"lg\"\u003eSimplifies maintenance by indicating system faults or operating abnormalities.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2330\" data-end=\"2447\"\u003e\n\u003ctd data-start=\"2330\" data-end=\"2360\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2332\" data-end=\"2359\"\u003eOptional Drain Pump Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2360\" data-end=\"2447\" data-col-size=\"lg\"\u003eOptional drain pump kit supports easier condensation drainage from the indoor unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2448\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2448\" data-end=\"2469\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2450\" data-end=\"2468\"\u003eDurable Casing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2469\" data-end=\"2564\" data-col-size=\"lg\"\u003eGalvanised steel plate casing supports strength and durability in commercial installations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2692\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2595\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2567\" data-end=\"2594\"\u003eLarge Space Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2595\" data-end=\"2692\" data-col-size=\"lg\"\u003eSuitable for warehouses, factories, showrooms, large offices, and high-load commercial areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2694\" data-end=\"2697\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2699\" data-end=\"2722\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2724\" data-end=\"3538\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2724\" data-end=\"2751\"\u003e\n\u003ctr data-start=\"2724\" data-end=\"2751\"\u003e\n\u003cth data-start=\"2724\" data-end=\"2740\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2740\" data-end=\"2751\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2762\" data-end=\"3538\"\u003e\n\u003ctr data-start=\"2762\" data-end=\"2789\"\u003e\n\u003ctd data-start=\"2762\" data-end=\"2774\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2764\" data-end=\"2773\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2774\" data-end=\"2789\" data-col-size=\"sm\"\u003eFXMQ200NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2790\" data-end=\"2833\"\u003e\n\u003ctd data-start=\"2790\" data-end=\"2809\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2792\" data-end=\"2808\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2809\" data-end=\"2833\" data-col-size=\"sm\"\u003e1 phase, 230V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2834\" data-end=\"2873\"\u003e\n\u003ctd data-start=\"2834\" data-end=\"2857\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2836\" data-end=\"2856\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2857\" data-end=\"2873\" data-col-size=\"sm\"\u003e76,400 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2874\" data-end=\"2908\"\u003e\n\u003ctd data-start=\"2874\" data-end=\"2897\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2876\" data-end=\"2896\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2897\" data-end=\"2908\" data-col-size=\"sm\"\u003e22.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2909\" data-end=\"2948\"\u003e\n\u003ctd data-start=\"2909\" data-end=\"2932\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2911\" data-end=\"2931\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2932\" data-end=\"2948\" data-col-size=\"sm\"\u003e83,300 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2949\" data-end=\"2983\"\u003e\n\u003ctd data-start=\"2949\" data-end=\"2972\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2951\" data-end=\"2971\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2972\" data-end=\"2983\" data-col-size=\"sm\"\u003e25.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2984\" data-end=\"3023\"\u003e\n\u003ctd data-start=\"2984\" data-end=\"2997\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2986\" data-end=\"2996\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2997\" data-end=\"3023\" data-col-size=\"sm\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3024\" data-end=\"3072\"\u003e\n\u003ctd data-start=\"3024\" data-end=\"3054\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3026\" data-end=\"3053\"\u003eAirflow Rate High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3054\" data-end=\"3072\" data-col-size=\"sm\"\u003e68 \/ 58 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3073\" data-end=\"3124\"\u003e\n\u003ctd data-start=\"3073\" data-end=\"3103\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3075\" data-end=\"3102\"\u003eAirflow Rate High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3103\" data-end=\"3124\" data-col-size=\"sm\"\u003e2,400 \/ 2,047 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3125\" data-end=\"3170\"\u003e\n\u003ctd data-start=\"3125\" data-end=\"3156\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3127\" data-end=\"3155\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3156\" data-end=\"3170\" data-col-size=\"sm\"\u003e100–200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3171\" data-end=\"3217\"\u003e\n\u003ctd data-start=\"3171\" data-end=\"3200\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3173\" data-end=\"3199\"\u003eSound Level High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3200\" data-end=\"3217\" data-col-size=\"sm\"\u003e47 \/ 45 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3218\" data-end=\"3271\"\u003e\n\u003ctd data-start=\"3218\" data-end=\"3245\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3220\" data-end=\"3244\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3245\" data-end=\"3271\" data-col-size=\"sm\"\u003e440 × 1,190 × 1,090 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3272\" data-end=\"3303\"\u003e\n\u003ctd data-start=\"3272\" data-end=\"3293\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3274\" data-end=\"3292\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3293\" data-end=\"3303\" data-col-size=\"sm\"\u003e110 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3304\" data-end=\"3351\"\u003e\n\u003ctd data-start=\"3304\" data-end=\"3333\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3306\" data-end=\"3332\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3333\" data-end=\"3351\" data-col-size=\"sm\"\u003eØ 9.5 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3352\" data-end=\"3399\"\u003e\n\u003ctd data-start=\"3352\" data-end=\"3378\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3354\" data-end=\"3377\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3378\" data-end=\"3399\" data-col-size=\"sm\"\u003eØ 19.1 mm brazing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3400\" data-end=\"3446\"\u003e\n\u003ctd data-start=\"3400\" data-end=\"3423\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3402\" data-end=\"3422\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3423\" data-end=\"3446\" data-col-size=\"sm\"\u003eExternal Dia. 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3447\" data-end=\"3507\"\u003e\n\u003ctd data-start=\"3447\" data-end=\"3471\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3449\" data-end=\"3470\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3471\" data-end=\"3507\" data-col-size=\"sm\"\u003eHigh static ceiling mounted duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3508\" data-end=\"3538\"\u003e\n\u003ctd data-start=\"3508\" data-end=\"3524\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3510\" data-end=\"3523\"\u003eFan Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3524\" data-end=\"3538\" data-col-size=\"sm\"\u003eHigh \/ Low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3540\" data-end=\"3543\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3545\" data-end=\"3565\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3567\" data-end=\"4196\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3567\" data-end=\"3597\"\u003e\n\u003ctr data-start=\"3567\" data-end=\"3597\"\u003e\n\u003cth data-start=\"3567\" data-end=\"3586\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3586\" data-end=\"3597\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3608\" data-end=\"4196\"\u003e\n\u003ctr data-start=\"3608\" data-end=\"3699\"\u003e\n\u003ctd data-start=\"3608\" data-end=\"3625\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3610\" data-end=\"3624\"\u003eWarehouses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3625\" data-end=\"3699\" data-col-size=\"md\"\u003eProvides strong ducted airflow for wide storage and operational areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3700\" data-end=\"3791\"\u003e\n\u003ctd data-start=\"3700\" data-end=\"3716\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3702\" data-end=\"3715\"\u003eFactories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3716\" data-end=\"3791\" data-col-size=\"md\"\u003eSuitable for production areas requiring high-capacity air conditioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3792\" data-end=\"3895\"\u003e\n\u003ctd data-start=\"3792\" data-end=\"3812\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3794\" data-end=\"3811\"\u003eLarge Offices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3812\" data-end=\"3895\" data-col-size=\"md\"\u003eIdeal for open-plan offices and commercial workspaces with ducted distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3896\" data-end=\"3987\"\u003e\n\u003ctd data-start=\"3896\" data-end=\"3912\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3898\" data-end=\"3911\"\u003eShowrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3912\" data-end=\"3987\" data-col-size=\"md\"\u003eHelps maintain comfortable cooling across large customer-facing spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3988\" data-end=\"4084\"\u003e\n\u003ctd data-start=\"3988\" data-end=\"4008\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3990\" data-end=\"4007\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4008\" data-end=\"4084\" data-col-size=\"md\"\u003eSuitable for large retail stores where concealed ducted AC is preferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4085\" data-end=\"4196\"\u003e\n\u003ctd data-start=\"4085\" data-end=\"4112\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4087\" data-end=\"4111\"\u003eCommercial Buildings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4112\" data-end=\"4196\" data-col-size=\"md\"\u003eWorks well in buildings requiring high static pressure and flexible duct design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4198\" data-end=\"4201\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4203\" data-end=\"4219\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4221\" data-end=\"4752\"\u003e\n\u003cli data-section-id=\"1c4e2ql\" data-start=\"4221\" data-end=\"4263\"\u003eHigh-capacity \u003cstrong data-start=\"4237\" data-end=\"4263\"\u003eVRV ducted indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jeoa8e\" data-start=\"4264\" data-end=\"4312\"\u003eCooling capacity of \u003cstrong data-start=\"4286\" data-end=\"4312\"\u003e22.4 kW \/ 76,400 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r4lyvr\" data-start=\"4313\" data-end=\"4361\"\u003eHeating capacity of \u003cstrong data-start=\"4335\" data-end=\"4361\"\u003e25.0 kW \/ 83,300 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3du4c5\" data-start=\"4362\" data-end=\"4405\"\u003eExternal static pressure up to \u003cstrong data-start=\"4395\" data-end=\"4405\"\u003e200 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xce1u6\" data-start=\"4406\" data-end=\"4458\"\u003eSuitable for large ducted air distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"s8yomt\" data-start=\"4459\" data-end=\"4504\"\u003eConcealed ceiling mounted duct installation\u003c\/li\u003e\n\u003cli data-section-id=\"17cb0s2\" data-start=\"4505\" data-end=\"4546\"\u003eHigh airflow rate of \u003cstrong data-start=\"4528\" data-end=\"4546\"\u003e68 \/ 58 m³\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ox2em7\" data-start=\"4547\" data-end=\"4586\"\u003eDurable galvanised steel plate casing\u003c\/li\u003e\n\u003cli data-section-id=\"hysetz\" data-start=\"4587\" data-end=\"4635\"\u003eSelf-diagnosis function for easier maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"22ggt3\" data-start=\"4636\" data-end=\"4669\"\u003eOptional drain pump kit support\u003c\/li\u003e\n\u003cli data-section-id=\"ym1scs\" data-start=\"4670\" data-end=\"4752\"\u003eIdeal for warehouses, factories, showrooms, offices, and commercial interiors ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47830396829932,"sku":null,"price":9699.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606231535-Copy_2.jpg?v=1782477201","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-ducted-splits-for-vrv-systems-6-3-ton-22-4-kw-8-5-hp-76-400-btu-h-fxmq200nve6","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}