{"product_id":"daikin-ducted-splits-for-vrv-systems-8-0-ton-28-0-kw-10-6-hp-95-500-btu-h-fxmq250nve6","title":"Daikin Ducted Splits for VRV Systems 8.0 Ton | 28.0 kW | 10.6 HP | 95,500 Btu\/h FXMQ250NVE6","description":"\u003cp data-start=\"174\" data-end=\"593\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"178\" data-end=\"200\"\u003eDaikin FXMQ250NVE6\u003c\/strong\u003e is a high-capacity VRV ceiling mounted ducted indoor unit designed for extra-large spaces that require powerful and reliable air conditioning. With a cooling capacity of \u003cstrong data-start=\"371\" data-end=\"382\"\u003e28.0 kW\u003c\/strong\u003e, heating capacity of \u003cstrong data-start=\"404\" data-end=\"415\"\u003e31.5 kW\u003c\/strong\u003e, and external static pressure up to \u003cstrong data-start=\"452\" data-end=\"462\"\u003e270 Pa\u003c\/strong\u003e, it is suitable for large commercial areas, factories, warehouses, offices, showrooms, and other demanding indoor environments. ❄️\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"595\" data-end=\"598\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"600\" data-end=\"615\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"617\" data-end=\"1169\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"617\" data-end=\"642\"\u003e\n\u003ctr data-start=\"617\" data-end=\"642\"\u003e\n\u003cth data-start=\"617\" data-end=\"627\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"627\" data-end=\"642\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"653\" data-end=\"1169\"\u003e\n\u003ctr data-start=\"653\" data-end=\"675\"\u003e\n\u003ctd data-start=\"653\" data-end=\"665\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"655\" data-end=\"664\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"665\" data-end=\"675\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"676\" data-end=\"703\"\u003e\n\u003ctd data-start=\"676\" data-end=\"688\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"678\" data-end=\"687\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"688\" data-end=\"703\" data-col-size=\"md\"\u003eFXMQ250NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"704\" data-end=\"730\"\u003e\n\u003ctd data-start=\"704\" data-end=\"717\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"706\" data-end=\"716\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"717\" data-end=\"730\" data-col-size=\"md\"\u003eFXMQ-NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"731\" data-end=\"776\"\u003e\n\u003ctd data-start=\"731\" data-end=\"750\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"733\" data-end=\"749\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"750\" data-end=\"776\" data-col-size=\"md\"\u003eVRV ducted indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"777\" data-end=\"837\"\u003e\n\u003ctd data-start=\"777\" data-end=\"801\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"779\" data-end=\"800\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"801\" data-end=\"837\" data-col-size=\"md\"\u003eHigh static ceiling mounted duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"838\" data-end=\"887\"\u003e\n\u003ctd data-start=\"838\" data-end=\"861\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"840\" data-end=\"860\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"861\" data-end=\"887\" data-col-size=\"md\"\u003e28.0 kW \/ 95,500 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"888\" data-end=\"938\"\u003e\n\u003ctd data-start=\"888\" data-end=\"911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"890\" data-end=\"910\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"911\" data-end=\"938\" data-col-size=\"md\"\u003e31.5 kW \/ 107,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"939\" data-end=\"982\"\u003e\n\u003ctd data-start=\"939\" data-end=\"958\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"941\" data-end=\"957\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"958\" data-end=\"982\" data-col-size=\"md\"\u003e1 phase, 230V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"983\" data-end=\"1028\"\u003e\n\u003ctd data-start=\"983\" data-end=\"1014\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"985\" data-end=\"1013\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1014\" data-end=\"1028\" data-col-size=\"md\"\u003e190–270 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1029\" data-end=\"1068\"\u003e\n\u003ctd data-start=\"1029\" data-end=\"1042\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1031\" data-end=\"1041\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1042\" data-end=\"1068\" data-col-size=\"md\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1069\" data-end=\"1169\"\u003e\n\u003ctd data-start=\"1069\" data-end=\"1087\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1071\" data-end=\"1086\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1087\" data-end=\"1169\" data-col-size=\"md\"\u003eExtra-large rooms, commercial spaces, factories, warehouses, and large offices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1171\" data-end=\"1174\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1176\" data-end=\"1195\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1197\" data-end=\"2669\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1197\" data-end=\"1218\"\u003e\n\u003ctr data-start=\"1197\" data-end=\"1218\"\u003e\n\u003cth data-start=\"1197\" data-end=\"1207\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1207\" data-end=\"1218\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1229\" data-end=\"2669\"\u003e\n\u003ctr data-start=\"1229\" data-end=\"1368\"\u003e\n\u003ctd data-start=\"1229\" data-end=\"1263\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1231\" data-end=\"1262\"\u003eHigh Static Pressure Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1263\" data-end=\"1368\" data-col-size=\"lg\"\u003eExternal static pressure up to \u003cstrong data-start=\"1296\" data-end=\"1306\"\u003e270 Pa\u003c\/strong\u003e supports long duct runs and large air distribution systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1369\" data-end=\"1500\"\u003e\n\u003ctd data-start=\"1369\" data-end=\"1397\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1371\" data-end=\"1396\"\u003eHigh Cooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1397\" data-end=\"1500\" data-col-size=\"lg\"\u003eProvides \u003cstrong data-start=\"1408\" data-end=\"1419\"\u003e28.0 kW\u003c\/strong\u003e cooling capacity for extra-large spaces and demanding commercial applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1501\" data-end=\"1603\"\u003e\n\u003ctd data-start=\"1501\" data-end=\"1533\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1532\"\u003ePowerful Heating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1533\" data-end=\"1603\" data-col-size=\"lg\"\u003eOffers \u003cstrong data-start=\"1542\" data-end=\"1553\"\u003e31.5 kW\u003c\/strong\u003e heating capacity for year-round indoor comfort.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1604\" data-end=\"1724\"\u003e\n\u003ctd data-start=\"1604\" data-end=\"1631\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1606\" data-end=\"1630\"\u003eLarge Airflow Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1631\" data-end=\"1724\" data-col-size=\"lg\"\u003eHigh airflow rate helps distribute conditioned air across large rooms and ducted layouts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1725\" data-end=\"1840\"\u003e\n\u003ctd data-start=\"1725\" data-end=\"1750\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1727\" data-end=\"1749\"\u003eTwo-Step Fan Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1750\" data-end=\"1840\" data-col-size=\"lg\"\u003eHigh and low fan speed operation allows airflow adjustment according to comfort needs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1841\" data-end=\"1981\"\u003e\n\u003ctd data-start=\"1841\" data-end=\"1867\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1843\" data-end=\"1866\"\u003eDucted Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1867\" data-end=\"1981\" data-col-size=\"lg\"\u003eCeiling mounted ducted design keeps the indoor unit concealed while supplying air through ducts and diffusers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1982\" data-end=\"2102\"\u003e\n\u003ctd data-start=\"1982\" data-end=\"2006\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1984\" data-end=\"2005\"\u003eClean Air Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2006\" data-end=\"2102\" data-col-size=\"lg\"\u003eAir filter helps remove airborne dust particles and supports cleaner indoor air circulation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2103\" data-end=\"2198\"\u003e\n\u003ctd data-start=\"2103\" data-end=\"2123\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2105\" data-end=\"2122\"\u003eDry Programme\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2123\" data-end=\"2198\" data-col-size=\"lg\"\u003eHelps reduce humidity levels without major changes in room temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2199\" data-end=\"2311\"\u003e\n\u003ctd data-start=\"2199\" data-end=\"2229\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2201\" data-end=\"2228\"\u003eSelf-Diagnosis Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2229\" data-end=\"2311\" data-col-size=\"lg\"\u003eSimplifies maintenance by indicating system faults or operating abnormalities.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2312\" data-end=\"2429\"\u003e\n\u003ctd data-start=\"2312\" data-end=\"2342\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2314\" data-end=\"2341\"\u003eOptional Drain Pump Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2342\" data-end=\"2429\" data-col-size=\"lg\"\u003eOptional drain pump kit supports easier condensation drainage from the indoor unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2430\" data-end=\"2545\"\u003e\n\u003ctd data-start=\"2430\" data-end=\"2451\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2432\" data-end=\"2450\"\u003eDurable Casing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2451\" data-end=\"2545\" data-col-size=\"lg\"\u003eGalvanised steel plate casing supports durability in commercial installation environments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2546\" data-end=\"2669\"\u003e\n\u003ctd data-start=\"2546\" data-end=\"2576\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2548\" data-end=\"2575\"\u003eLarge Space Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2576\" data-end=\"2669\" data-col-size=\"lg\"\u003eSuitable for factories, warehouses, showrooms, large offices, and other high-load spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2671\" data-end=\"2674\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2676\" data-end=\"2699\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2701\" data-end=\"3516\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2701\" data-end=\"2728\"\u003e\n\u003ctr data-start=\"2701\" data-end=\"2728\"\u003e\n\u003cth data-start=\"2701\" data-end=\"2717\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2717\" data-end=\"2728\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2739\" data-end=\"3516\"\u003e\n\u003ctr data-start=\"2739\" data-end=\"2766\"\u003e\n\u003ctd data-start=\"2739\" data-end=\"2751\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2741\" data-end=\"2750\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2751\" data-end=\"2766\" data-col-size=\"sm\"\u003eFXMQ250NVE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2767\" data-end=\"2810\"\u003e\n\u003ctd data-start=\"2767\" data-end=\"2786\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2769\" data-end=\"2785\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2786\" data-end=\"2810\" data-col-size=\"sm\"\u003e1 phase, 230V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2811\" data-end=\"2850\"\u003e\n\u003ctd data-start=\"2811\" data-end=\"2834\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2813\" data-end=\"2833\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2834\" data-end=\"2850\" data-col-size=\"sm\"\u003e95,500 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2851\" data-end=\"2885\"\u003e\n\u003ctd data-start=\"2851\" data-end=\"2874\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2853\" data-end=\"2873\"\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2874\" data-end=\"2885\" data-col-size=\"sm\"\u003e28.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2886\" data-end=\"2926\"\u003e\n\u003ctd data-start=\"2886\" data-end=\"2909\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2888\" data-end=\"2908\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2909\" data-end=\"2926\" data-col-size=\"sm\"\u003e107,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2927\" data-end=\"2961\"\u003e\n\u003ctd data-start=\"2927\" data-end=\"2950\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2929\" data-end=\"2949\"\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2950\" data-end=\"2961\" data-col-size=\"sm\"\u003e31.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2962\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2962\" data-end=\"2975\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2964\" data-end=\"2974\"\u003eCasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2975\" data-end=\"3001\" data-col-size=\"sm\"\u003eGalvanised steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3050\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3032\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3004\" data-end=\"3031\"\u003eAirflow Rate High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3032\" data-end=\"3050\" data-col-size=\"sm\"\u003e80 \/ 73 m³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3051\" data-end=\"3102\"\u003e\n\u003ctd data-start=\"3051\" data-end=\"3081\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3053\" data-end=\"3080\"\u003eAirflow Rate High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3081\" data-end=\"3102\" data-col-size=\"sm\"\u003e2,825 \/ 2,578 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3103\" data-end=\"3148\"\u003e\n\u003ctd data-start=\"3103\" data-end=\"3134\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3105\" data-end=\"3133\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3134\" data-end=\"3148\" data-col-size=\"sm\"\u003e190–270 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3149\" data-end=\"3195\"\u003e\n\u003ctd data-start=\"3149\" data-end=\"3178\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3151\" data-end=\"3177\"\u003eSound Level High \/ Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3178\" data-end=\"3195\" data-col-size=\"sm\"\u003e49 \/ 47 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3196\" data-end=\"3249\"\u003e\n\u003ctd data-start=\"3196\" data-end=\"3223\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3198\" data-end=\"3222\"\u003eDimensions H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3223\" data-end=\"3249\" data-col-size=\"sm\"\u003e440 × 1,490 × 1,090 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3250\" data-end=\"3281\"\u003e\n\u003ctd data-start=\"3250\" data-end=\"3271\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3252\" data-end=\"3270\"\u003eMachine Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3271\" data-end=\"3281\" data-col-size=\"sm\"\u003e130 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3282\" data-end=\"3329\"\u003e\n\u003ctd data-start=\"3282\" data-end=\"3311\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3284\" data-end=\"3310\"\u003eLiquid Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3311\" data-end=\"3329\" data-col-size=\"sm\"\u003eØ 9.5 mm flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3330\" data-end=\"3377\"\u003e\n\u003ctd data-start=\"3330\" data-end=\"3356\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3332\" data-end=\"3355\"\u003eGas Pipe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3356\" data-end=\"3377\" data-col-size=\"sm\"\u003eØ 22.2 mm brazing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3378\" data-end=\"3424\"\u003e\n\u003ctd data-start=\"3378\" data-end=\"3401\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3380\" data-end=\"3400\"\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3401\" data-end=\"3424\" data-col-size=\"sm\"\u003eExternal Dia. 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3425\" data-end=\"3485\"\u003e\n\u003ctd data-start=\"3425\" data-end=\"3449\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3427\" data-end=\"3448\"\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3449\" data-end=\"3485\" data-col-size=\"sm\"\u003eHigh static ceiling mounted duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3486\" data-end=\"3516\"\u003e\n\u003ctd data-start=\"3486\" data-end=\"3502\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3488\" data-end=\"3501\"\u003eFan Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3502\" data-end=\"3516\" data-col-size=\"sm\"\u003eHigh \/ Low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3518\" data-end=\"3521\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3523\" data-end=\"3543\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3545\" data-end=\"4204\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3545\" data-end=\"3575\"\u003e\n\u003ctr data-start=\"3545\" data-end=\"3575\"\u003e\n\u003cth data-start=\"3545\" data-end=\"3564\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3564\" data-end=\"3575\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3586\" data-end=\"4204\"\u003e\n\u003ctr data-start=\"3586\" data-end=\"3690\"\u003e\n\u003ctd data-start=\"3586\" data-end=\"3602\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3588\" data-end=\"3601\"\u003eFactories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3602\" data-end=\"3690\" data-col-size=\"md\"\u003eSuitable for large production areas requiring high-capacity ducted air conditioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3691\" data-end=\"3779\"\u003e\n\u003ctd data-start=\"3691\" data-end=\"3708\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3693\" data-end=\"3707\"\u003eWarehouses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3708\" data-end=\"3779\" data-col-size=\"md\"\u003eProvides powerful airflow for wide indoor spaces and storage areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3780\" data-end=\"3883\"\u003e\n\u003ctd data-start=\"3780\" data-end=\"3800\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3782\" data-end=\"3799\"\u003eLarge Offices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3800\" data-end=\"3883\" data-col-size=\"md\"\u003eIdeal for open-plan offices and commercial workspaces requiring ducted cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3884\" data-end=\"3980\"\u003e\n\u003ctd data-start=\"3884\" data-end=\"3900\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3886\" data-end=\"3899\"\u003eShowrooms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3900\" data-end=\"3980\" data-col-size=\"md\"\u003eHelps maintain comfortable temperatures across large customer-facing spaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3981\" data-end=\"4089\"\u003e\n\u003ctd data-start=\"3981\" data-end=\"4001\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3983\" data-end=\"4000\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4001\" data-end=\"4089\" data-col-size=\"md\"\u003eSuitable for large retail areas where concealed ducted AC installation is preferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4090\" data-end=\"4204\"\u003e\n\u003ctd data-start=\"4090\" data-end=\"4117\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4092\" data-end=\"4116\"\u003eCommercial Buildings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4117\" data-end=\"4204\" data-col-size=\"md\"\u003eWorks well in buildings requiring high static pressure and large duct distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4206\" data-end=\"4209\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"4211\" data-end=\"4227\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"4229\" data-end=\"4768\"\u003e\n\u003cli data-section-id=\"1c4e2ql\" data-start=\"4229\" data-end=\"4271\"\u003eHigh-capacity \u003cstrong data-start=\"4245\" data-end=\"4271\"\u003eVRV ducted indoor unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uslmks\" data-start=\"4272\" data-end=\"4320\"\u003eCooling capacity of \u003cstrong data-start=\"4294\" data-end=\"4320\"\u003e28.0 kW \/ 95,500 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xmni09\" data-start=\"4321\" data-end=\"4370\"\u003eHeating capacity of \u003cstrong data-start=\"4343\" data-end=\"4370\"\u003e31.5 kW \/ 107,000 Btu\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bk662a\" data-start=\"4371\" data-end=\"4414\"\u003eExternal static pressure up to \u003cstrong data-start=\"4404\" data-end=\"4414\"\u003e270 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ayt4lw\" data-start=\"4415\" data-end=\"4479\"\u003eSuitable for long duct runs and large air distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"s8yomt\" data-start=\"4480\" data-end=\"4525\"\u003eConcealed ceiling mounted duct installation\u003c\/li\u003e\n\u003cli data-section-id=\"c1csnx\" data-start=\"4526\" data-end=\"4567\"\u003eHigh airflow rate of \u003cstrong data-start=\"4549\" data-end=\"4567\"\u003e80 \/ 73 m³\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ox2em7\" data-start=\"4568\" data-end=\"4607\"\u003eDurable galvanised steel plate casing\u003c\/li\u003e\n\u003cli data-section-id=\"hysetz\" data-start=\"4608\" data-end=\"4656\"\u003eSelf-diagnosis function for easier maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"22ggt3\" data-start=\"4657\" data-end=\"4690\"\u003eOptional drain pump kit support\u003c\/li\u003e\n\u003cli data-section-id=\"fcfdgy\" data-start=\"4691\" data-end=\"4768\"\u003eIdeal for factories, warehouses, large offices, and commercial interiors ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47830394306796,"sku":null,"price":10699.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606231535.jpg?v=1782477088","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-ducted-splits-for-vrv-systems-8-0-ton-28-0-kw-10-6-hp-95-500-btu-h-fxmq250nve6","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}