{"product_id":"daikin-vrv-outdoor-unit-8-0-ton-28-0-kw-10-0-hp-95-500-btu-h-rxq10aryfk","title":"Daikin VRV Outdoor Unit 8.0 Ton 28.0 kW 10.0 HP 95,500 Btu\/h RXQ10ARYFK","description":"\u003cp data-start=\"148\" data-end=\"533\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"190\"\u003eDaikin RXQ10ARYFK VRV Cooling Only\u003c\/strong\u003e is a high-performance outdoor VRV air conditioning system designed for \u003cstrong data-start=\"262\" data-end=\"289\"\u003ehigh ambient conditions\u003c\/strong\u003e. It uses advanced \u003cstrong data-start=\"308\" data-end=\"350\"\u003eVariable Refrigerant Temperature (VRT)\u003c\/strong\u003e technology to continuously adjust inverter compressor speed and refrigerant temperature according to the building load, helping provide efficient, stable, and comfortable cooling. ❄️\u003c\/p\u003e\n\u003chr data-start=\"535\" data-end=\"538\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"540\" data-end=\"555\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"557\" data-end=\"1165\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"557\" data-end=\"582\"\u003e\n\u003ctr data-start=\"557\" data-end=\"582\"\u003e\n\u003cth data-start=\"557\" data-end=\"567\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"567\" data-end=\"582\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"593\" data-end=\"1165\"\u003e\n\u003ctr data-start=\"593\" data-end=\"615\"\u003e\n\u003ctd data-start=\"593\" data-end=\"605\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"595\" data-end=\"604\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"605\" data-end=\"615\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"616\" data-end=\"642\"\u003e\n\u003ctd data-start=\"616\" data-end=\"628\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"618\" data-end=\"627\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"628\" data-end=\"642\" data-col-size=\"md\"\u003eRXQ10ARYFK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"643\" data-end=\"665\"\u003e\n\u003ctd data-start=\"643\" data-end=\"656\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"645\" data-end=\"655\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"656\" data-end=\"665\" data-col-size=\"md\"\u003eVRV X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"666\" data-end=\"717\"\u003e\n\u003ctd data-start=\"666\" data-end=\"684\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"668\" data-end=\"683\"\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"684\" data-end=\"717\" data-col-size=\"md\"\u003eVRV Cooling Only Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"718\" data-end=\"768\"\u003e\n\u003ctd data-start=\"718\" data-end=\"741\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"720\" data-end=\"740\"\u003eApplication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"741\" data-end=\"768\" data-col-size=\"md\"\u003eHigh Ambient Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"769\" data-end=\"833\"\u003e\n\u003ctd data-start=\"769\" data-end=\"791\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"771\" data-end=\"790\"\u003eMain Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"791\" data-end=\"833\" data-col-size=\"md\"\u003eVariable Refrigerant Temperature \/ VRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"834\" data-end=\"881\"\u003e\n\u003ctd data-start=\"834\" data-end=\"856\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"836\" data-end=\"855\"\u003eCompressor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"856\" data-end=\"881\" data-col-size=\"md\"\u003eNew scroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"882\" data-end=\"917\"\u003e\n\u003ctd data-start=\"882\" data-end=\"901\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"884\" data-end=\"900\"\u003eCooling Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"901\" data-end=\"917\" data-col-size=\"md\"\u003eCooling Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"918\" data-end=\"1014\"\u003e\n\u003ctd data-start=\"918\" data-end=\"943\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"920\" data-end=\"942\"\u003eEfficiency Benefit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"943\" data-end=\"1014\" data-col-size=\"md\"\u003eUp to 28% seasonal efficiency increase compared to conventional VRF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1015\" data-end=\"1062\"\u003e\n\u003ctd data-start=\"1015\" data-end=\"1045\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1017\" data-end=\"1044\"\u003eOutdoor Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1045\" data-end=\"1062\" data-col-size=\"md\"\u003eUp to 78.4 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1063\" data-end=\"1165\"\u003e\n\u003ctd data-start=\"1063\" data-end=\"1081\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1080\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1081\" data-end=\"1165\" data-col-size=\"md\"\u003eVillas, offices, hotels, retail spaces, commercial buildings, and large projects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1167\" data-end=\"1170\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1172\" data-end=\"1191\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1193\" data-end=\"2491\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1193\" data-end=\"1214\"\u003e\n\u003ctr data-start=\"1193\" data-end=\"1214\"\u003e\n\u003cth data-start=\"1193\" data-end=\"1203\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1203\" data-end=\"1214\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1225\" data-end=\"2491\"\u003e\n\u003ctr data-start=\"1225\" data-end=\"1393\"\u003e\n\u003ctd data-start=\"1225\" data-end=\"1264\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1227\" data-end=\"1263\"\u003eVariable Refrigerant Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1264\" data-end=\"1393\" data-col-size=\"lg\"\u003eContinuously adjusts refrigerant temperature and inverter compressor speed to meet the actual cooling demand of the building.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1394\" data-end=\"1514\"\u003e\n\u003ctd data-start=\"1394\" data-end=\"1425\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1396\" data-end=\"1424\"\u003eHigh Seasonal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1425\" data-end=\"1514\" data-col-size=\"lg\"\u003eDelivers up to 28% higher seasonal efficiency compared with conventional VRF systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1515\" data-end=\"1642\"\u003e\n\u003ctd data-start=\"1515\" data-end=\"1550\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1549\"\u003eWeather Compensating Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1550\" data-end=\"1642\" data-col-size=\"lg\"\u003eHelps improve indoor comfort with higher outblow temperatures and reduced cold draughts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1643\" data-end=\"1764\"\u003e\n\u003ctd data-start=\"1643\" data-end=\"1671\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1645\" data-end=\"1670\"\u003eNew Scroll Compressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1671\" data-end=\"1764\" data-col-size=\"lg\"\u003eMinimizes refrigerant leakage during low-load operation for stable and efficient cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1765\" data-end=\"1908\"\u003e\n\u003ctd data-start=\"1765\" data-end=\"1804\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1767\" data-end=\"1803\"\u003eHighly Integrated Heat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1804\" data-end=\"1908\" data-col-size=\"lg\"\u003eImproves performance by increasing heat exchanger area while maintaining compact installation space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1909\" data-end=\"2022\"\u003e\n\u003ctd data-start=\"1909\" data-end=\"1940\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1911\" data-end=\"1939\"\u003eAnti-Corrosion Treatment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1940\" data-end=\"2022\" data-col-size=\"lg\"\u003eProvides 5 to 6 times greater resistance against acid rain and salt corrosion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2023\" data-end=\"2119\"\u003e\n\u003ctd data-start=\"2023\" data-end=\"2052\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2025\" data-end=\"2051\"\u003eRefrigerant-Cooled PCB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2052\" data-end=\"2119\" data-col-size=\"lg\"\u003eImproves reliability during high ambient temperature operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2120\" data-end=\"2249\"\u003e\n\u003ctd data-start=\"2120\" data-end=\"2156\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2122\" data-end=\"2155\"\u003eHigh External Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2156\" data-end=\"2249\" data-col-size=\"lg\"\u003eSupports up to 78.4 Pa for flexible outdoor unit arrangement and stable heat dissipation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2250\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2250\" data-end=\"2288\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2252\" data-end=\"2287\"\u003eFlexible Indoor Unit Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2288\" data-end=\"2374\" data-col-size=\"lg\"\u003eCompatible with a variety of indoor unit types for different project requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2491\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2408\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2377\" data-end=\"2407\"\u003eFresh Air Handling Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2408\" data-end=\"2491\" data-col-size=\"lg\"\u003eCan connect with fresh air handling units to support better indoor air quality.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2493\" data-end=\"2496\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2498\" data-end=\"2521\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2523\" data-end=\"3247\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2523\" data-end=\"2550\"\u003e\n\u003ctr data-start=\"2523\" data-end=\"2550\"\u003e\n\u003cth data-start=\"2523\" data-end=\"2539\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2539\" data-end=\"2550\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2561\" data-end=\"3247\"\u003e\n\u003ctr data-start=\"2561\" data-end=\"2587\"\u003e\n\u003ctd data-start=\"2561\" data-end=\"2573\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2563\" data-end=\"2572\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2587\" data-col-size=\"md\"\u003eRXQ10ARYFK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2588\" data-end=\"2610\"\u003e\n\u003ctd data-start=\"2588\" data-end=\"2601\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2590\" data-end=\"2600\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2601\" data-end=\"2610\" data-col-size=\"md\"\u003eVRV X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2611\" data-end=\"2662\"\u003e\n\u003ctd data-start=\"2611\" data-end=\"2629\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2613\" data-end=\"2628\"\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2629\" data-end=\"2662\" data-col-size=\"md\"\u003eCooling Only VRV Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2663\" data-end=\"2722\"\u003e\n\u003ctd data-start=\"2663\" data-end=\"2680\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2665\" data-end=\"2679\"\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2680\" data-end=\"2722\" data-col-size=\"md\"\u003eVariable Refrigerant Temperature \/ VRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2723\" data-end=\"2765\"\u003e\n\u003ctd data-start=\"2723\" data-end=\"2740\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2725\" data-end=\"2739\"\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2740\" data-end=\"2765\" data-col-size=\"md\"\u003eNew scroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2766\" data-end=\"2846\"\u003e\n\u003ctd data-start=\"2766\" data-end=\"2804\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2768\" data-end=\"2803\"\u003eSeasonal Efficiency Improvement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2804\" data-end=\"2846\" data-col-size=\"md\"\u003eUp to 28% compared to conventional VRF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2847\" data-end=\"2895\"\u003e\n\u003ctd data-start=\"2847\" data-end=\"2878\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2849\" data-end=\"2877\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2878\" data-end=\"2895\"\u003eUp to 78.4 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2896\" data-end=\"2958\"\u003e\n\u003ctd data-start=\"2896\" data-end=\"2922\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2898\" data-end=\"2921\"\u003eOperating Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2922\" data-end=\"2958\" data-col-size=\"md\"\u003eHigh ambient climate application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2959\" data-end=\"3016\"\u003e\n\u003ctd data-start=\"2959\" data-end=\"2980\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2961\" data-end=\"2979\"\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2980\" data-end=\"3016\" data-col-size=\"md\"\u003eHighly integrated heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3017\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3017\" data-end=\"3035\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3019\" data-end=\"3034\"\u003ePCB Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3035\" data-end=\"3061\" data-col-size=\"md\"\u003eRefrigerant-cooled PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3125\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3089\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3064\" data-end=\"3088\"\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3089\" data-end=\"3125\" data-col-size=\"md\"\u003eSpecial anti-corrosion treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3126\" data-end=\"3201\"\u003e\n\u003ctd data-start=\"3126\" data-end=\"3155\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3128\" data-end=\"3154\"\u003eIndoor Unit Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3155\" data-end=\"3201\" data-col-size=\"md\"\u003eSupports multiple indoor unit combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3202\" data-end=\"3247\"\u003e\n\u003ctd data-start=\"3202\" data-end=\"3240\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3204\" data-end=\"3239\"\u003eFresh Air Handling Unit Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3240\" data-end=\"3247\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3249\" data-end=\"3252\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3254\" data-end=\"3274\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3276\" data-end=\"3868\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3276\" data-end=\"3306\"\u003e\n\u003ctr data-start=\"3276\" data-end=\"3306\"\u003e\n\u003cth data-start=\"3276\" data-end=\"3295\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3295\" data-end=\"3306\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3317\" data-end=\"3868\"\u003e\n\u003ctr data-start=\"3317\" data-end=\"3391\"\u003e\n\u003ctd data-start=\"3317\" data-end=\"3330\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3319\" data-end=\"3329\"\u003eHotels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3330\" data-end=\"3391\" data-col-size=\"md\"\u003eSuitable for multi-zone cooling in hospitality buildings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3392\" data-end=\"3473\"\u003e\n\u003ctd data-start=\"3392\" data-end=\"3406\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3394\" data-end=\"3405\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3406\" data-end=\"3473\" data-col-size=\"md\"\u003eProvides efficient cooling for different work areas and floors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3474\" data-end=\"3567\"\u003e\n\u003ctd data-start=\"3474\" data-end=\"3494\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3476\" data-end=\"3493\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3494\" data-end=\"3567\" data-col-size=\"md\"\u003eHelps maintain comfortable indoor conditions for customers and staff.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3568\" data-end=\"3661\"\u003e\n\u003ctd data-start=\"3568\" data-end=\"3595\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3570\" data-end=\"3594\"\u003eCommercial Buildings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3595\" data-end=\"3661\" data-col-size=\"md\"\u003eIdeal for larger HVAC projects requiring reliable VRV cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3662\" data-end=\"3756\"\u003e\n\u003ctd data-start=\"3662\" data-end=\"3698\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3664\" data-end=\"3697\"\u003eVillas \u0026amp; Residential Projects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3698\" data-end=\"3756\"\u003eSuitable for premium centralized cooling applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3757\" data-end=\"3868\"\u003e\n\u003ctd data-start=\"3757\" data-end=\"3786\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3759\" data-end=\"3785\"\u003eHigh Ambient Locations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3786\" data-end=\"3868\" data-col-size=\"md\"\u003eDesigned for hot climate regions where stable cooling performance is required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3870\" data-end=\"3873\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"3875\" data-end=\"3891\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"3893\" data-end=\"4537\"\u003e\n\u003cli data-section-id=\"1frg7gx\" data-start=\"3893\" data-end=\"3954\"\u003e\n\u003cstrong data-start=\"3895\" data-end=\"3917\"\u003eVRV X cooling only\u003c\/strong\u003e system for high ambient conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1kxkbmj\" data-start=\"3955\" data-end=\"4015\"\u003eAdvanced \u003cstrong data-start=\"3966\" data-end=\"4002\"\u003eVariable Refrigerant Temperature\u003c\/strong\u003e technology\u003c\/li\u003e\n\u003cli data-section-id=\"170zm8q\" data-start=\"4016\" data-end=\"4094\"\u003eUp to \u003cstrong data-start=\"4024\" data-end=\"4063\"\u003e28% seasonal efficiency improvement\u003c\/strong\u003e compared to conventional VRF\u003c\/li\u003e\n\u003cli data-section-id=\"l0zk35\" data-start=\"4095\" data-end=\"4155\"\u003eWeather compensating control for improved indoor comfort\u003c\/li\u003e\n\u003cli data-section-id=\"htfj3y\" data-start=\"4156\" data-end=\"4211\"\u003eNew scroll compressor for stable low-load operation\u003c\/li\u003e\n\u003cli data-section-id=\"1hroj8v\" data-start=\"4212\" data-end=\"4278\"\u003eRefrigerant-cooled PCB for better high-temperature reliability\u003c\/li\u003e\n\u003cli data-section-id=\"4z8bhj\" data-start=\"4279\" data-end=\"4348\"\u003eHighly integrated heat exchanger for improved cooling performance\u003c\/li\u003e\n\u003cli data-section-id=\"b6wmn1\" data-start=\"4349\" data-end=\"4413\"\u003eSpecial anti-corrosion treatment for long-lasting durability\u003c\/li\u003e\n\u003cli data-section-id=\"c0rtb0\" data-start=\"4414\" data-end=\"4465\"\u003eHigh external static pressure up to \u003cstrong data-start=\"4452\" data-end=\"4463\"\u003e78.4 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xrcu9m\" data-start=\"4466\" data-end=\"4537\"\u003eFlexible connection with indoor units and fresh air handling units ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47784984412396,"sku":null,"price":24349.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606231509-Copy_4.jpg?v=1782378128","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-vrv-outdoor-unit-8-0-ton-28-0-kw-10-0-hp-95-500-btu-h-rxq10aryfk","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}