{"product_id":"daikin-vrv-outdoor-unit-9-5-ton-33-5-kw-12-0-hp-114-000-btu-h-rxq12aryfk","title":"Daikin VRV Outdoor Unit 9.5 Ton 33.5 kW 12.0 HP 114,000 Btu\/h RXQ12ARYFK","description":"\u003cp data-start=\"148\" data-end=\"538\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"190\"\u003eDaikin RXQ12ARYFK VRV Cooling Only\u003c\/strong\u003e is a high-performance outdoor VRV air conditioning system designed for \u003cstrong data-start=\"262\" data-end=\"289\"\u003ehigh ambient conditions\u003c\/strong\u003e. It uses advanced \u003cstrong data-start=\"308\" data-end=\"350\"\u003eVariable Refrigerant Temperature (VRT)\u003c\/strong\u003e technology to continuously adjust both inverter compressor speed and refrigerant temperature according to the building load, helping deliver efficient, stable, and comfortable cooling. ❄️\u003c\/p\u003e\n\u003chr data-start=\"540\" data-end=\"543\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"545\" data-end=\"560\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"562\" data-end=\"1170\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"562\" data-end=\"587\"\u003e\n\u003ctr data-start=\"562\" data-end=\"587\"\u003e\n\u003cth data-start=\"562\" data-end=\"572\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"572\" data-end=\"587\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"598\" data-end=\"1170\"\u003e\n\u003ctr data-start=\"598\" data-end=\"620\"\u003e\n\u003ctd data-start=\"598\" data-end=\"610\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"600\" data-end=\"609\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"610\" data-end=\"620\" data-col-size=\"md\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"621\" data-end=\"647\"\u003e\n\u003ctd data-start=\"621\" data-end=\"633\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"623\" data-end=\"632\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"633\" data-end=\"647\" data-col-size=\"md\"\u003eRXQ12ARYFK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"648\" data-end=\"670\"\u003e\n\u003ctd data-start=\"648\" data-end=\"661\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"650\" data-end=\"660\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"661\" data-end=\"670\" data-col-size=\"md\"\u003eVRV X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"671\" data-end=\"722\"\u003e\n\u003ctd data-start=\"671\" data-end=\"689\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"673\" data-end=\"688\"\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"689\" data-end=\"722\" data-col-size=\"md\"\u003eVRV Cooling Only Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"723\" data-end=\"773\"\u003e\n\u003ctd data-start=\"723\" data-end=\"746\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"725\" data-end=\"745\"\u003eApplication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"746\" data-end=\"773\" data-col-size=\"md\"\u003eHigh Ambient Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"774\" data-end=\"838\"\u003e\n\u003ctd data-start=\"774\" data-end=\"796\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"776\" data-end=\"795\"\u003eMain Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"796\" data-end=\"838\"\u003eVariable Refrigerant Temperature \/ VRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"839\" data-end=\"886\"\u003e\n\u003ctd data-start=\"839\" data-end=\"861\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"841\" data-end=\"860\"\u003eCompressor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"861\" data-end=\"886\"\u003eNew scroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"887\" data-end=\"922\"\u003e\n\u003ctd data-start=\"887\" data-end=\"906\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"889\" data-end=\"905\"\u003eCooling Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"906\" data-end=\"922\" data-col-size=\"md\"\u003eCooling Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"923\" data-end=\"1019\"\u003e\n\u003ctd data-start=\"923\" data-end=\"948\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"925\" data-end=\"947\"\u003eEfficiency Benefit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"948\" data-end=\"1019\"\u003eUp to 28% seasonal efficiency increase compared to conventional VRF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1020\" data-end=\"1067\"\u003e\n\u003ctd data-start=\"1020\" data-end=\"1050\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1049\"\u003eOutdoor Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1050\" data-end=\"1067\"\u003eUp to 78.4 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1068\" data-end=\"1170\"\u003e\n\u003ctd data-start=\"1068\" data-end=\"1086\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1070\" data-end=\"1085\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1086\" data-end=\"1170\" data-col-size=\"md\"\u003eVillas, offices, hotels, retail spaces, commercial buildings, and large projects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1172\" data-end=\"1175\"\u003e\n\u003ch2 data-section-id=\"736h55\" data-start=\"1177\" data-end=\"1196\"\u003eProduct Features\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1198\" data-end=\"2512\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1198\" data-end=\"1219\"\u003e\n\u003ctr data-start=\"1198\" data-end=\"1219\"\u003e\n\u003cth data-start=\"1198\" data-end=\"1208\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1208\" data-end=\"1219\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1230\" data-end=\"2512\"\u003e\n\u003ctr data-start=\"1230\" data-end=\"1390\"\u003e\n\u003ctd data-start=\"1230\" data-end=\"1269\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1232\" data-end=\"1268\"\u003eVariable Refrigerant Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1269\" data-end=\"1390\" data-col-size=\"lg\"\u003eContinuously adjusts refrigerant temperature and inverter compressor speed to match the actual building cooling load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1391\" data-end=\"1511\"\u003e\n\u003ctd data-start=\"1391\" data-end=\"1422\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1393\" data-end=\"1421\"\u003eHigh Seasonal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"1422\" data-end=\"1511\"\u003eDelivers up to 28% higher seasonal efficiency compared with conventional VRF systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1512\" data-end=\"1632\"\u003e\n\u003ctd data-start=\"1512\" data-end=\"1547\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1514\" data-end=\"1546\"\u003eWeather Compensating Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1547\" data-end=\"1632\" data-col-size=\"lg\"\u003eHelps improve comfort with higher outblow temperatures and reduced cold draughts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1633\" data-end=\"1754\"\u003e\n\u003ctd data-start=\"1633\" data-end=\"1661\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1635\" data-end=\"1660\"\u003eNew Scroll Compressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1661\" data-end=\"1754\" data-col-size=\"lg\"\u003eMinimizes refrigerant leakage during low-load operation for stable and efficient cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1755\" data-end=\"1908\"\u003e\n\u003ctd data-start=\"1755\" data-end=\"1794\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1793\"\u003eHighly Integrated Heat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"1794\" data-end=\"1908\"\u003eImproves heat exchange performance by increasing heat exchanger area while keeping installation space compact.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1909\" data-end=\"2022\"\u003e\n\u003ctd data-start=\"1909\" data-end=\"1940\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1911\" data-end=\"1939\"\u003eAnti-Corrosion Treatment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1940\" data-end=\"2022\" data-col-size=\"lg\"\u003eProvides 5 to 6 times greater resistance against acid rain and salt corrosion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2023\" data-end=\"2133\"\u003e\n\u003ctd data-start=\"2023\" data-end=\"2052\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2025\" data-end=\"2051\"\u003eRefrigerant-Cooled PCB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2052\" data-end=\"2133\"\u003eImproves reliability during operation in high ambient temperature conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2134\" data-end=\"2269\"\u003e\n\u003ctd data-start=\"2134\" data-end=\"2170\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2136\" data-end=\"2169\"\u003eHigh External Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2170\" data-end=\"2269\"\u003eSupports up to 78.4 Pa, allowing flexible outdoor unit arrangement and stable heat dissipation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2270\" data-end=\"2390\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2308\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2272\" data-end=\"2307\"\u003eFlexible Indoor Unit Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2308\" data-end=\"2390\"\u003eCompatible with multiple indoor unit types for different project requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2391\" data-end=\"2512\"\u003e\n\u003ctd data-start=\"2391\" data-end=\"2424\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2393\" data-end=\"2423\"\u003eFresh Air Handling Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2424\" data-end=\"2512\"\u003eCan be connected with fresh air handling units to support better indoor air quality.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2514\" data-end=\"2517\"\u003e\n\u003ch2 data-section-id=\"1hh064s\" data-start=\"2519\" data-end=\"2542\"\u003eTechnical Parameters\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2544\" data-end=\"3268\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2544\" data-end=\"2571\"\u003e\n\u003ctr data-start=\"2544\" data-end=\"2571\"\u003e\n\u003cth data-start=\"2544\" data-end=\"2560\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2560\" data-end=\"2571\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2582\" data-end=\"3268\"\u003e\n\u003ctr data-start=\"2582\" data-end=\"2608\"\u003e\n\u003ctd data-start=\"2582\" data-end=\"2594\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2584\" data-end=\"2593\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2594\" data-end=\"2608\" data-col-size=\"md\"\u003eRXQ12ARYFK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2609\" data-end=\"2631\"\u003e\n\u003ctd data-start=\"2609\" data-end=\"2622\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2611\" data-end=\"2621\"\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2622\" data-end=\"2631\"\u003eVRV X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2632\" data-end=\"2683\"\u003e\n\u003ctd data-start=\"2632\" data-end=\"2650\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2634\" data-end=\"2649\"\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2683\" data-col-size=\"md\"\u003eCooling Only VRV Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2684\" data-end=\"2743\"\u003e\n\u003ctd data-start=\"2684\" data-end=\"2701\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2700\"\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2701\" data-end=\"2743\" data-col-size=\"md\"\u003eVariable Refrigerant Temperature \/ VRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2744\" data-end=\"2786\"\u003e\n\u003ctd data-start=\"2744\" data-end=\"2761\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2746\" data-end=\"2760\"\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2761\" data-end=\"2786\"\u003eNew scroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2787\" data-end=\"2867\"\u003e\n\u003ctd data-start=\"2787\" data-end=\"2825\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2789\" data-end=\"2824\"\u003eSeasonal Efficiency Improvement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2825\" data-end=\"2867\" data-col-size=\"md\"\u003eUp to 28% compared to conventional VRF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2868\" data-end=\"2916\"\u003e\n\u003ctd data-start=\"2868\" data-end=\"2899\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2870\" data-end=\"2898\"\u003eExternal Static Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2899\" data-end=\"2916\" data-col-size=\"md\"\u003eUp to 78.4 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2917\" data-end=\"2979\"\u003e\n\u003ctd data-start=\"2917\" data-end=\"2943\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2919\" data-end=\"2942\"\u003eOperating Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2943\" data-end=\"2979\"\u003eHigh ambient climate application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2980\" data-end=\"3037\"\u003e\n\u003ctd data-start=\"2980\" data-end=\"3001\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2982\" data-end=\"3000\"\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3001\" data-end=\"3037\" data-col-size=\"md\"\u003eHighly integrated heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3038\" data-end=\"3082\"\u003e\n\u003ctd data-start=\"3038\" data-end=\"3056\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3040\" data-end=\"3055\"\u003ePCB Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3056\" data-end=\"3082\" data-col-size=\"md\"\u003eRefrigerant-cooled PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3083\" data-end=\"3146\"\u003e\n\u003ctd data-start=\"3083\" data-end=\"3110\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3085\" data-end=\"3109\"\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3110\" data-end=\"3146\" data-col-size=\"md\"\u003eSpecial anti-corrosion treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3147\" data-end=\"3222\"\u003e\n\u003ctd data-start=\"3147\" data-end=\"3176\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3149\" data-end=\"3175\"\u003eIndoor Unit Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3176\" data-end=\"3222\"\u003eSupports multiple indoor unit combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3223\" data-end=\"3268\"\u003e\n\u003ctd data-start=\"3223\" data-end=\"3261\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3225\" data-end=\"3260\"\u003eFresh Air Handling Unit Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3261\" data-end=\"3268\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3270\" data-end=\"3273\"\u003e\n\u003ch2 data-section-id=\"3l7kwl\" data-start=\"3275\" data-end=\"3295\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3297\" data-end=\"3889\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3297\" data-end=\"3327\"\u003e\n\u003ctr data-start=\"3297\" data-end=\"3327\"\u003e\n\u003cth data-start=\"3297\" data-end=\"3316\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eApplication Area\u003c\/th\u003e\n\u003cth data-start=\"3316\" data-end=\"3327\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3338\" data-end=\"3889\"\u003e\n\u003ctr data-start=\"3338\" data-end=\"3412\"\u003e\n\u003ctd data-start=\"3338\" data-end=\"3351\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3340\" data-end=\"3350\"\u003eHotels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3351\" data-end=\"3412\" data-col-size=\"md\"\u003eSuitable for multi-zone cooling in hospitality buildings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3413\" data-end=\"3494\"\u003e\n\u003ctd data-start=\"3413\" data-end=\"3427\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3415\" data-end=\"3426\"\u003eOffices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3427\" data-end=\"3494\" data-col-size=\"md\"\u003eProvides efficient cooling for different work areas and floors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3495\" data-end=\"3588\"\u003e\n\u003ctd data-start=\"3495\" data-end=\"3515\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3497\" data-end=\"3514\"\u003eRetail Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3515\" data-end=\"3588\" data-col-size=\"md\"\u003eHelps maintain comfortable indoor conditions for customers and staff.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3589\" data-end=\"3682\"\u003e\n\u003ctd data-start=\"3589\" data-end=\"3616\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3591\" data-end=\"3615\"\u003eCommercial Buildings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3616\" data-end=\"3682\" data-col-size=\"md\"\u003eIdeal for larger HVAC projects requiring reliable VRV cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3683\" data-end=\"3777\"\u003e\n\u003ctd data-start=\"3683\" data-end=\"3719\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3685\" data-end=\"3718\"\u003eVillas \u0026amp; Residential Projects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3719\" data-end=\"3777\" data-col-size=\"md\"\u003eSuitable for premium centralized cooling applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3778\" data-end=\"3889\"\u003e\n\u003ctd data-start=\"3778\" data-end=\"3807\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3780\" data-end=\"3806\"\u003eHigh Ambient Locations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3807\" data-end=\"3889\" data-col-size=\"md\"\u003eDesigned for hot climate regions where stable cooling performance is required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3891\" data-end=\"3894\"\u003e\n\u003ch2 data-section-id=\"s6awsq\" data-start=\"3896\" data-end=\"3912\"\u003eMain Benefits\u003c\/h2\u003e\n\u003cul data-start=\"3914\" data-end=\"4558\"\u003e\n\u003cli data-section-id=\"1frg7gx\" data-start=\"3914\" data-end=\"3975\"\u003e\n\u003cstrong data-start=\"3916\" data-end=\"3938\"\u003eVRV X cooling only\u003c\/strong\u003e system for high ambient conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1kxkbmj\" data-start=\"3976\" data-end=\"4036\"\u003eAdvanced \u003cstrong data-start=\"3987\" data-end=\"4023\"\u003eVariable Refrigerant Temperature\u003c\/strong\u003e technology\u003c\/li\u003e\n\u003cli data-section-id=\"170zm8q\" data-start=\"4037\" data-end=\"4115\"\u003eUp to \u003cstrong data-start=\"4045\" data-end=\"4084\"\u003e28% seasonal efficiency improvement\u003c\/strong\u003e compared to conventional VRF\u003c\/li\u003e\n\u003cli data-section-id=\"l0zk35\" data-start=\"4116\" data-end=\"4176\"\u003eWeather compensating control for improved indoor comfort\u003c\/li\u003e\n\u003cli data-section-id=\"htfj3y\" data-start=\"4177\" data-end=\"4232\"\u003eNew scroll compressor for stable low-load operation\u003c\/li\u003e\n\u003cli data-section-id=\"1hroj8v\" data-start=\"4233\" data-end=\"4299\"\u003eRefrigerant-cooled PCB for better high-temperature reliability\u003c\/li\u003e\n\u003cli data-section-id=\"4z8bhj\" data-start=\"4300\" data-end=\"4369\"\u003eHighly integrated heat exchanger for improved cooling performance\u003c\/li\u003e\n\u003cli data-section-id=\"b6wmn1\" data-start=\"4370\" data-end=\"4434\"\u003eSpecial anti-corrosion treatment for long-lasting durability\u003c\/li\u003e\n\u003cli data-section-id=\"c0rtb0\" data-start=\"4435\" data-end=\"4486\"\u003eHigh external static pressure up to \u003cstrong data-start=\"4473\" data-end=\"4484\"\u003e78.4 Pa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xrcu9m\" data-start=\"4487\" data-end=\"4558\"\u003eFlexible connection with indoor units and fresh air handling units ⚙️\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47784532771052,"sku":null,"price":26869.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/Use_the_uploaded_product_image_202606231509-Copy_3.jpg?v=1782373805","url":"https:\/\/www.fajtradingllc.com\/products\/daikin-vrv-outdoor-unit-9-5-ton-33-5-kw-12-0-hp-114-000-btu-h-rxq12aryfk","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}