{"product_id":"kalton-refrigerant-gas-r-22","title":"KALTON REFRIGERANT GAS R‑22","description":"\u003cp\u003e\u003cstrong\u003eKALTON Refrigerant Gas R-22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HCFC-22 \/ CHClF₂) is a high-purity refrigerant widely used for servicing older residential, commercial, and industrial HVAC systems. Known for its stable cooling performance and reliability, R-22 has long been used in medium- and low-temperature refrigeration applications including split ACs, cold rooms, chillers, and packaged units.\u003c\/p\u003e\n\u003cp\u003eAlthough highly effective, R-22 is regulated globally due to its ozone depletion potential. It is only permitted for maintenance of existing systems and cannot be used in new installations. KALTON R-22 meets international quality standards and is packaged in high-strength steel cylinders.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Cooling Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProven efficiency for medium \u0026amp; low-temperature systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA1 Safety Classification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-flammable and low-toxicity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with MO \u0026amp; AB Oils:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWorks with mineral and alkylbenzene lubricants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Purity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≥ 99.9% purity ensures stable, moisture-free system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineered for Legacy Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePerfect for servicing existing R-22-based equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy residential split AC units\u003c\/li\u003e\n\u003cli\u003eWindow AC systems\u003c\/li\u003e\n\u003cli\u003ePackaged \u0026amp; ducted HVAC units\u003c\/li\u003e\n\u003cli\u003eIndustrial chillers \u0026amp; cold room systems\u003c\/li\u003e\n\u003cli\u003eMedium \u0026amp; low-temperature refrigeration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCylinder Dimensions \u0026amp; Handling\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: approx. 45–48 cm\u003c\/li\u003e\n\u003cli\u003eDiameter: approx. 23–25 cm\u003c\/li\u003e\n\u003cli\u003eHigh-strength steel cylinder with corrosion-resistant coating\u003c\/li\u003e\n\u003cli\u003eStore upright at temperatures between 0–45 °C\u003c\/li\u003e\n\u003cli\u003eAvoid exposure to heat or direct sunlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUsage Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eonly for servicing existing R-22 systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echarge R-22 into R-410A, R-407C, or R-32 systems.\u003c\/li\u003e\n\u003cli\u003eFollow proper refrigerant recovery and recycling protocols.\u003c\/li\u003e\n\u003cli\u003eUse compatible lubricants: mineral oil or alkylbenzene.\u003c\/li\u003e\n\u003cli\u003eCheck system seals, filters, and driers before charging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRegulatory Notice\u003c\/h2\u003e\n\u003cp\u003eR-22 is under global phase-out regulations (Montreal Protocol). Its sale is permitted only for maintenance of existing systems and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot for new installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eSafety \u0026amp; Storage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNon-flammable, A1 safety\u003c\/li\u003e\n\u003cli\u003eWear gloves and eye protection during charging\u003c\/li\u003e\n\u003cli\u003eEnsure proper ventilation when servicing\u003c\/li\u003e\n\u003cli\u003eStore cylinders upright in cool, shaded areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Is Kalton R-22 still available?\u003c\/strong\u003e\u003cbr\u003eYes, but only for servicing existing systems where regulations allow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can R-22 be used in new AC units?\u003c\/strong\u003e\u003cbr\u003eNo. New systems must use alternative refrigerants such as R-410A or R-32.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What oil is compatible with R-22?\u003c\/strong\u003e\u003cbr\u003eMineral oil (MO) or alkylbenzene (AB), depending on the compressor type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is R-22 flammable?\u003c\/strong\u003e\u003cbr\u003eNo. It is classified A1—non-flammable and safe under normal use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Do I need to follow special handling rules?\u003c\/strong\u003e\u003cbr\u003eYes. Recovery, recycling, and environmental compliance are mandatory.\u003cstrong data-start=\"2\" data-end=\"12\" data-is-only-node=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47701683011820,"sku":null,"price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/138329cb-7f72-4230-be22-add8def339f6.webp?v=1780552136","url":"https:\/\/www.fajtradingllc.com\/products\/kalton-refrigerant-gas-r-22","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}