{"product_id":"kalton-refrigerant-gas-r-407c","title":"KALTON REFRIGERANT GAS R‑407C","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eKALTON Refrigerant Gas R-407C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency HFC refrigerant blend designed as a reliable and eco-friendly replacement for HCFC R-22. With a composition of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR-32, R-125, and R-134a\u003c\/strong\u003e, R-407C delivers pressure-temperature characteristics similar to R-22, making it the preferred choice for retrofit and upgrade projects. It offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eZero Ozone Depletion Potential (ODP = 0)\u003c\/strong\u003e, stable cooling performance, and low toxicity, making it suitable for residential, commercial, and industrial HVAC environments.\u003c\/p\u003e\n\u003cp\u003eIts strong thermodynamic behavior and energy-efficient operation ensure long-term reliability for split ACs, heat pumps, rooftop units, and medium-temperature refrigeration systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero ODP:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnvironmentally safer alternative to R-22.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-22 Performance Match:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSimilar pressure-temperature characteristics facilitate retrofitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong Cooling Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStable system performance across varied conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomical Retrofit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for converting older R-22 systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA1 Safety Class:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-flammable, low-toxicity refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Purity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≥ 99.9% moisture-free formula.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential split \u0026amp; window AC retrofits\u003c\/li\u003e\n\u003cli\u003eCommercial ducted units \u0026amp; rooftop HVAC systems\u003c\/li\u003e\n\u003cli\u003eHeat pumps\u003c\/li\u003e\n\u003cli\u003eMedium-temperature refrigeration systems\u003c\/li\u003e\n\u003cli\u003eR-22 replacement in compatible HVAC equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCylinder Dimensions \u0026amp; Handling\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight (10–24 kg cylinders): approx. 46–50 cm\u003c\/li\u003e\n\u003cli\u003eDiameter: approx. 23–27 cm\u003c\/li\u003e\n\u003cli\u003eHigh-strength steel with corrosion protection\u003c\/li\u003e\n\u003cli\u003eStore upright between 0–45 °C in ventilated areas\u003c\/li\u003e\n\u003cli\u003eAvoid direct heat or ignition sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUsage Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eonly in R-407C systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor R-22 retrofits.\u003c\/li\u003e\n\u003cli\u003eMandatory\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOE oil conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(mineral\/AB oil not compatible).\u003c\/li\u003e\n\u003cli\u003eCharge\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eas liquid\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain blend consistency.\u003c\/li\u003e\n\u003cli\u003eReplace filter-drier, evacuate system, and perform leak tests.\u003c\/li\u003e\n\u003cli\u003eAccount for temperature glide in evaporator design \u0026amp; superheat settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSafety \u0026amp; Storage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA1 non-flammable refrigerant\u003c\/li\u003e\n\u003cli\u003eUse PPE: gloves and goggles\u003c\/li\u003e\n\u003cli\u003eEnsure mechanical ventilation when charging\u003c\/li\u003e\n\u003cli\u003eStore cylinders upright in cool, dry areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Is R-407C a direct drop-in replacement for R-22?\u003c\/strong\u003e\u003cbr\u003eNo. It requires proper retrofit steps including oil change, line flushing, and liquid charging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is temperature glide?\u003c\/strong\u003e\u003cbr\u003eA phase-change temperature difference (~7–8°C) that affects evaporator design and superheat settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can R-407C be used instead of R-410A?\u003c\/strong\u003e\u003cbr\u003eNo. R-407C operates at different pressures and is better suited for R-22 retrofits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What oil is compatible with R-407C?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePOE (Polyolester) oil only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Is R-407C safe?\u003c\/strong\u003e\u003cbr\u003eYes—classified A1, non-flammable and low toxicity.\u003cstrong data-start=\"2\" data-end=\"12\" data-is-only-node=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"F A J Trading L.L.C","offers":[{"title":"Default Title","offer_id":47701678850284,"sku":null,"price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0706\/8139\/5436\/files\/4e48b0ec-77d5-42c9-b746-9a1247891c5c.webp?v=1780551638","url":"https:\/\/www.fajtradingllc.com\/products\/kalton-refrigerant-gas-r-407c","provider":"F A J Trading L.L.C","version":"1.0","type":"link"}